Parameter
Operation selection at power failure
FR-A700 EC
6 - 337
6.16
Operation selection at power failure
6.16.1
Automatic restart (Pr. 57, Pr. 58, Pr. 162 to Pr. 165, Pr. 299, Pr. 611)
You can restart the inverter without stopping the motor in the following cases.
●
when commercial power supply operation is switched to inverter operation
●
when power comes back on after an instantaneous power failure
●
when motor is coasting at start
Purpose
Parameters that must be set
Refer to
Section
At instantaneous power failure
occurrence, restart inverter without
stopping motor.
Automatic restart operation after
instantaneous power failure
Pr. 57, Pr. 58,
Pr. 162–Pr. 165,
Pr. 299, Pr. 611
When under voltage or a power fail-
ure occurs, the inverter can be
decelerated to a stop.
Power failure-time deceleration-to-stop
function
Pr. 261–Pr. 266