Speed control by real sensorless vector control, vector control
Parameter
6 - 88
6.3.3
To perform high accuracy/fast response operation (gain adjustment of
real sensorless vector control and vector control)
(Pr. 818 to Pr. 821, Pr. 830, Pr. 831, Pr. 880)
The ratio of the load inertia to the motor inertia (load inertia moment) is estimated in real time
from the torque command and speed during motor operation by vector control. As optimum gain
of speed control and position control are automatically set from the load inertia ratio and
response level, time and effort of making gain adjustment are reduced. (Easy gain tuning)
When the load inertia ratio can not be estimated due to load fluctuation or real sensorless vector
control is exercised, control gain is automatically set by manually inputting the load inertia ratio.
Make a manual input adjustment when vibration, noise or any other unfavorable phenomenon
occurs due to large load inertia or gear backlash, for example, or when you want to exhibit the
best performance that matches the machine.
Pr.
No.
Name
Initial
Value
Setting Range
Description
Parameters referred to
Refer to
Section
818
Easy gain tuning
response level set-
ting
2
1–15
Set the response level.
1: Slow response
to
15: Fast reponse
—
819
Easy gain tuning
selection
0
0
Without easy gain tuning
1
With load estimation, with gain calcu-
lation
(valid only during vector control)
2
With load (Pr. 880) manual input,
gain calculation
820
Speed control P
gain 1
60%
0–1000%
Set the proportional gain for speed
control.
(Increasing the value improves track-
ability in response to a speed com-
mand change and reduces speed
variation with disturbance.)
821
Speed control
integral time 1
0.333s
0–20s
Set the integral time during speed
control.
(Decrease the value to shorten the
time taken for returning to the origi-
nal speed if speed variation with dis-
turbance occurs.)
830
Speed control P
gain 2
9999
0–1000%
Second function of Pr. 820
(valid when RT signal is on)
9999
No function
831
Speed control
integral time 2
9999
0–20s
Second function of Pr. 821
(valid when RT signal is on)
9999
No function
880
Load inertia ratio
7
0–200
Set the load intertia ratio to the
motor.
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
Содержание FR-A700 EC
Страница 2: ......
Страница 4: ......
Страница 24: ...Description of the Case Product Checking and Part Identification 1 4 ...
Страница 38: ...Enclosure design Installation 2 14 ...
Страница 774: ...Specifications FR A 740 01800 to 12120 Appendix A 4 ...
Страница 820: ...Parameter list with instruction codes Appendix A 50 ...
Страница 825: ......