![Mitsubishi Electric FR-A700-A1 Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/mitsubishi-electric/fr-a700-a1/fr-a700-a1_instruction-manual_239747022.webp)
19
Parameter setting procedure for dancer
control function
3.5 Parameter setting procedure for dancer control function
The following flowchart shows the parameter setting example for the dancer control.
Start
Basic setting
Select control method according to
the application and the motor.
Applied motor selection
(Pr. 71)
Motor capacity
(Pr. 80)
Number of motor poles
(Pr. 81)
Control method selection
(Pr. 800)
Number of encoder pulses
(Pr. 369)
Select any of V/F control, Advanced magnetic flux vector control, Real
sensorless vector control (speed control), or vector control (speed control) to
perform winding with dancer control.
Gain
adjustment of
speed control
Adjust gain of speed control.
Refer to page
for gain adjustment of speed control with Real sensorless
vector control/Vector control.
Input signal
setting
Main speed setting
(Refer to page 43 )
Setting with analog input voltage
(terminal 2)
Set parameters below.
C2 Terminal 2 frequency setting bias
frequency
= "0r/min"
Pr. 125 Terminal 2 frequency setting
gain frequency
= "Maximum speed"
C3 Terminal 2 frequency setting bias
=
"0%"
C4 Terminal 2 frequency setting gain
=
"100%"
Setting with pulse train input
(terminal JOG)
Set parameters below according to
the input pulse frequency.
Pr. 384 Input pulse division scaling
factor
"0"
Pr. 385 Frequency for zero input pulse
= "0r/min"
Pr. 386 Frequency for maximum input
pulse
= "Maximum speed"
Pr. 703 Minimum number of input
pulse
= "0"
Pr.704 Maximum number of input pulse
= "Maximum number of pulses"
Setting with digital input
(FR-A7AX)
Set parameters below according to
BCD and binary code signals.
Pr. 304 Digital input and analog input
compensation enable/disable selection
Pr. 300 BCD input bias
Pr. 301 BCD input gain
Pr. 302 BIN input bias
Pr. 303 BIN input gain
Pr. 305 Read timing operation selection
Pr. 329 Digital input unit selection
Assign X83 by setting "83" in any of
Input terminal function selection (Pr. 178
to Pr. 189)
.
Dancer
control
function
selection
Set action determined by polarity of
dancer roll position detection signal
(terminal 1 input
) with
Pr. 128 PID
action selection
(Refer to page 25 )
Set Pr. 762 Winding/unwinding
selection. (Refer to page 34 )
For winding :
Pr. 762
= "0"
For unwinding :
Pr. 762
= "1"
Set
Pr. 128
= "40" to accelerate when dancer roll position detection signal
(terminal 1 input
) is negative.
Set
Pr. 128
= "41" to accelerate when dancer roll position detection signal
(terminal 1 input
) is positive.
*1
Use
Pr. 732
to change the input terminal for the main speed commands.
*3
Use
Pr. 731
to change the terminal for the dancer roll position detection.
See the next page.
POINT
Set X83 signal ON to activate dancer control.
*2
Maximum rotation number:
max
Maximum number of rotation at the fastest line speed with minimum diameter
(maximum diameter) for winding (unwinding).
max
=
V
max
r/min
D
min
(D
max
)
Z