Features
Options
Precautions
Motor
Connection
example
Standard
specs.
Outline
dimensions
Parameter
list
Parameter
descriptions
Protective
functions
IPM motor
control
Compatibility
W
arranty
Te
rminal connection
diagrams
T
e
rminal specs.
Operation panel
Parameter unit
FR Configurator
59
Options and peripheral devices
A Filterpack (FR-BFP2) is enclosed with the FR-F7
0PJ-
KF inverters.
Rated power consumption.The power supply specifications of the FR series manual controllers and speed controllers are 200VAC 50Hz, 220/220VAC 60Hz,
and 115VAC 60Hz.
List of options
Name
Model
Applications, Specifications, etc.
Applicable
Inverter
S
tand-al
one
type
Parameter unit
(Eight languages)
FR-PU07
Interactive parameter unit with LCD display
Applicable for all
models
Enclosure surface operation
panel
FR-PA07
This operation panel enables inverter operation and monitoring of
frequency, etc. from the enclosure surface
Applicable for all
models
Parameter unit connection
cable
FR-CB20
Cable for connection of operation panel or parameter unit
indicates a
cable length. (1m, 3m, 5m)
Applicable for all
models
DIN rail attachment
FR-UDA01 to 03
Attachment for installation on DIN rail
Applicable for the
3.7K or lower
AC reactor
FR-HAL
For harmonic current reduction and inverter input power factor
improvement
Applicable for the
certain capacities
DC reactor
FR-HEL
EMC Directive compliant EMC
filter
SF
FR-E5NF
An EMC filter that complies with the EMC Directive (EN61800-3 C3).
Applicable for the
certain capacities
EMC filter installation attachment
FR-A5AT03
An attachment used to mount an EMC compliant EMC filter (SF) to an
inverter.
Applicable for the
certain capacities
FR-AAT02
FR-E5T
Radio noise filter
FR-BIF(H)
For radio noise reduction (connect to the input side)
Applicable for all
models
Line noise filter
FR-BSF01
FR-BLF
For line noise reduction
Applicable for all
models
Filterpack
FR-BFP2
A Filterpack that contains a power factor improving DC reactor,
common mode choke, and capacitive filter (radio noise filter) in one.
Applicable for the
certain capacities
Brake resistor
MRS type,
MYS type
For increasing the regenerative braking capability (permissible duty
3%/6%ED)
200V: Applicable
for the certain
capacities
High-duty brake resistor
FR-ABR
For increasing the regenerative braking capability (permissible duty
10%/ 6%ED)
Applicable for the
certain capacities
Brake unit
Resistor unit
Discharging resistor
FR-BU2
FR-BR
GZG, GRZG type
For increasing the braking capability of the inverter (for high-inertia load
or negative load)
Brake unit, electrical-discharge resistor and resistor unit are used in
combination
Applicable for the
certain capacities
Power regeneration common
converter
Stand-alone reactor dedicated for
FR-CV
FR-CV
FR-CVL
Unit which can return motor-generated braking energy back to the
power supply in common converter system
Applicable for the
certain capacities
High power factor converter
FR-HC2
The high power factor converter switches the converter section on/off to
reshape an input current waveform into a sine wave, greatly
suppressing harmonics. (Used in combination with the standard
accessory.)
Applicable for the
certain capacities
Surge voltage suppression filter
FR-ASF-H
Filter for suppressing surge voltage on motor
400V: Applicable
for the certain
capacities
FR-BMF-H
400V: applicable
for the 5.5K or
higher
FR Se
ri
es
Manual
Controll
er/
S
p
eed c
ontroll
er
Manual controller
FR-AX
For independent operation. With frequency meter, frequency
potentiometer and start switch.
Applicable for all
models
DC tach. follower
FR-AL
For synchronous operation (1VA) by external signal (0 to 5V, 0 to 10V DC)
Three speed selector
FR-AT
For three speed switching, among high, middle and low speed
operation (1.5VA)
Motorized speed setter
FR-FK
For remote operation. Allows operation to be controlled from several
places (5VA)
Ratio setter
FR-FH
For ratio operation. Allows ratios to be set to five inverters. (3VA)
PG follower
FR-FP
For tracking operation by a pilot generator (PG) signal (2VA)
Master controller
FR-FG
Master controller (5VA) for parallel operation of multiple (maximum 35)
inverters.
Soft starter
FR-FC
For soft start and stop. Enables acceleration/deceleration in parallel
operation (3VA)
Deviation detector
FR-FD
For continuous speed control operation. Used in combination with a
deviation sensor or synchro (5VA)
Preamplifier
FR-FA
Used as an A/V converter or arithmetic amplifier (3VA)
Ot
h
e
rs
Pilot generator
QVAH-10
For tracking operation. 70V/35VAC 500Hz (at 2500r/min)
Deviation sensor
YVGC-500W-NS
For continuous speed control operation (mechanical deviation detection).
Output 90VAC/90°
Frequency setting
potentiometer
WA2W 1k
For frequency setting. Wire-wound 2W 1k
type B characteristic
Frequency meter (64mm
60mm) YM206NRI 1mA
Dedicated frequency meter (graduated to 130Hz). Moving-coil type DC
ammeter
Calibration resistor
RV24YN 10k
For frequency meter calibration. Carbon film type B characteristic
FR Configurator
(Inverter setup software)
FR-SW3-
SETUP-WE
Supports an inverter startup to maintenance
Содержание F720PJ-11KF