Product Lineup
Specifications
Examples of
EcoMonitorLight
Applications
External View
Names and
Functions of
Each Part
Connection
Configurations
/Wiring Precautions
Communication
Unit Wiring and
Setting Procedures
Energy measuring
devices
Model Name/
Specifications
Safety
Precautions
Device
Installation
Procedures
Features
Memo
Product Lineup
Specifications
Examples of EcoMonitorLight Applications
External View
Names and Functions of Each Part
Connection Configurations /Wiring Precautions
Communication Unit Wiring and Setting Procedures
Energy measuring devices
Model Name/ Specifications
Safety Precautions
Device Installation Procedures
Features
Memo
14
13
Main Screen
Main Screen
Graph Screen
Parameters Settings Screen
Current Value Screen
Alarm Screen
Current Values Monitor Screen
Features of EcoWebServerⅢ
Connection to PLC System
6
Connection to EcoWebServerⅢ System
7
Examples of GOT1000 Series Applications
5
Available uses include preventive equipment maintenance by using energy amount measurement and real-time measurement of
each piece of production equipment, and linking of quality control indicators with production information.
Adding a communication unit to an already installed energy measuring unit allows you to use the EcoWebServer
Ⅲ
system to
visualize energy and perform simple analysis of measurement data.
You can directly connect to the Mitsubishi GOT* by using MODBUS
®
RTU communication.
Displaying various energy information on a GOT installed on-site allows you to improve on-site energy-conservation
awareness and perform production management to fit the energy conditions.
A sample Mitsubishi GOT*
1
screens are provided.
You can view current values of various energy information such as power, current and voltage, and also display graphs of current and electric energy*
2
.
You can download the sample GOT screen free of charge from the Mitsubishi Electric FA website.
MODBUS
®
RTU (RS485) Communication Connection*
CC-Link Communication Connection*
*In order to connect with a PLC, a module that is compatible with MODBUS
®
RTU (RS485) communication is required.
*In order to connect with a PLC, a unit that is compatible with CC-Link communication is required.
Sample Screen
GOT1000 Series
EcoWebServerⅢ
(Energy-Saving Data Collecting Server) Catalog
MODBUS
®
RTU
Communication (RS485)
What is EcoWebServerⅢ?
(1)Reduces unnecessary labor and cost by collecting energy information from various measurement terminals, and
storing and visualizing data without the need for programming.
(2)Measurement data can be viewed in graphs of zoom (1 minute and 5 minutes ), daily, monthly and annual formats.
(3)Production information can be captured to display specific consumption rate graphs.
EcoWebServer
Ⅲ
is a device that collects the data of various measurement terminals using CC-Link communication network, and displays graphs of
measurement data (such as power, current and voltage) and current value data in a Web browser.
■On-site Visualization of Energy Data
For customers who want on-site visualization of energy consumption, and to manage the
correlation of Production and energy!
[
GOT1000 MODBUS
®
RTU
(
RS485
)
Communication Application
]
■Energy Management with PLC
For custormers who want to capture energy information in the PLC system, and manage
production information and other types of data in an integrated manner.
■EcoWebServerⅢ
EcoWebServer
Ⅲ
(Energy-Saving Data Collecting
Server) and CC-Link Communication Unit Application
You can use MODBUS
®
RTU communication to
directly connect to a Mitsubishi GOT*.
MODBUS
®
RTU
(RS485) Communication
*Compatible with GOT1000 series units that are standard-equipped with an RS485 serial port
■GT10
■GT14
*1: GT14**-Q, GT1030 *2: Only compatible with GT14**-Q.
3.Examples of EcoMonitorLight Applications
3.Examples of EcoMonitorLight Applications
CC-Link
Communication
CC-Link
Communication
LAN
Содержание EMU4-BD1-MB
Страница 9: ......