![Mitsubishi Electric E1071 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/mitsubishi-electric/e1071/e1071_installation-manual_240958007.webp)
Installation
Mitsubishi Electric, MA00777A
2-1
2
Installation
2.1 Space Requirements
– Installation plate thickness: 1.5 - 9.0 mm (0.06 - 0.35 inch)
– Space requirements when installing the operator terminal:
Caution
The openings on the enclosure are for air convection. Do not cover these openings.
2.2 Installation Process
1. Unpack and check the delivery. If damage is found, notify the supplier
.
Note:
Place the operator terminal on a stable surface during installation.
Dropping it or letting it fall may cause damage.
2. Place the panel cut out where the operator terminal is to be situated, draw along
the outer sides of the holes and cut according to the markings.
50 mm
154 mm
219 mm
(2.0 inch)
50 mm
(2.0 inch)
100 mm
(4.0 inch)
100 mm
(4.0 inch)
100 mm
(4.0 inch)
55 mm
(2.17 inch)
(8.62 inch)
(6.06 inch)
x
4
Pa
n
el
c
ut out
188.5
x
1
3
7.5 mm
(7.42
x
5.41 inch)
Содержание E1071
Страница 1: ...MITSUBISHI ELECTRIC E1071 Installation manual MA00777A 2006 04 English ...
Страница 4: ...Table of Contents Mitsubishi Electric MA00777A ...
Страница 10: ...Installation 2 4 Mitsubishi Electric MA00777A ...
Страница 12: ...Technical Data 3 2 Mitsubishi Electric MA00777A ...
Страница 18: ...Operator Terminal Drawings 5 2 Mitsubishi Electric MA00777 5 2 E1071 Outline Drawing No S 5055 Date 2004 10 26 ...