– 20 –
4.5
Checking the recorder’s operation status and executing instant
operations
You can check the recorder’s operation status with the recorder status indicators on the main window (
see 3.3
on page 9). Indication of the recorder’s operation status is automatically updated every 3 minutes by default. You
can change the update interval (
see 4.18.1 on page 37) and update the indication manually (
see 3.5 on
page 11.) When you control the recorder using this software, the indication is always updated.
Only by double-clicking the status indicators, you can execute the operations indicated by them (except some
indicators). Note that these instant operations are available only when the following requirements are satisfied.
• You have logged in under the user ID having authority to operate the recorder.
• You have successfully logged in to the port to exert authority to operate the recorder.
• The recorder is ready to be operated. (For example, you can’t start recording when the recorder’s power is off.)
For relationship between user’s authority and the recorder ports,
see 4.13 on page 30.
4.6
Loading live images and audio
4.6.1
Loading live images
When accessing a recorder, this software automatically starts loading live images. To stop loading, use any of the
following methods.
• Click the Stop button on the camera window panel (
see 3.7 on page 12).
• Click [Stop] in the [Operation] menu on the camera window panel (
see 3.7 on page 12).
• Click the Stop button on the recorder panel (
see 3.5 on page 11).
• Click the Stop button on the Rec Panel Lite window (
see 3.8 on page 12).
The above-mentioned methods using the camera window panel stop loading live images of only the camera
corresponding to that camera window. The other methods stop loading live images of all the cameras connected to
the recorder. During loading of live images, the Live icon (
) is displayed on the camera window.
To restart loading live images, click the [Live] button on each panel or select [Live] in the [Operation] menu.
4.6.2
Loading live audio
You can hear live audio while loading live images. To hear live audio, display the camera window panel of the
recorder of which live audio you want to hear and select a channel using [Audio Ch].
Use the audio delay slide bar to determine the buffer amount of the audio data. As the audio delay is set shorter,
the delay between video data and audio data gets smaller, but a better communication environment and a recorder
condition with lighter load are required. Adjust this slider depending on your operation conditions.
Tips
• When band control is being applied to the recorder, ample communication band is not secured, or internal
processing with heavy load (such as recording, copying, motion detection by the recorder) is underway, it may
be impossible to load clear live audio. Further, the PC’s capacity may affect loading of live audio. In these
cases, secure the communication band by disconnecting some recorders, slowing the image refresh speed (
see 4.10.8 on page 29) , or reducing the image quality (
see 4.10.7 on page 29). When the PC’s capacity is
not adequate, decrease the decode level (
see 4.10.7 on page 29).
Double click the status
indicator.
[Live] button
Stop button