21
ENGLISH
<Error log> (continued)
LOG number
LOG display
example in the
client software
Cause
Remedy
Call-out
signal
output
Alert
level*1
5200
LOG5200
• The recorder is used in a high
temperature environment.
• Turn off the power and install the
recorder in an environment of 5 to 40
°C.
Output
Minor
5201
LOG5201
• The recorder is used in a high
temperature environment.
• Contact your dealer.
Output
Major
5300
LOG5300
• The fan stops.
• If the fan stops, turn off the power
and contact your dealer immediately.
Output
Major
8000
LOG8000
• An error occurs in LAN LINK.
• Check the LAN connection.
Does not
output
Minor
8501
LOG8501
• Recording stops temporarily because the
received data size becomes too large.
-
Does not
output
Minor
<Operation log>
LOG number
LOG display
example in the
client software
Operation
0001
P-LOSS
Power failure occurs during operation.
0002
P-RETURN
Power failure is recovered.
0110
REC OFF
Normal recording stops.
0111
REC ON
Normal recording starts.
0112
REC COM OFF
Normal recording stops via communucation.
0113
REC COM ON
Normal recording starts via communucation.
0501
SYS RST
RESET button on the rear panel is pressed.
0590
WNG RESET
The call-out output is stopped.
0900
FW VER.UP
Main
fi
rmware is updated.