Mitsubishi Electric Central Controller GB-50A Скачать руководство пользователя страница 7

 6

3-3 Setting Functions 

Make initial settings with either the Initial Setting Web or Initial Setting Tool. 

                                                            Table 3-3 List of initial-setting functions 

Item 

This Unit 

Initial Setting Tool

Initial Setting 

Web 

Remarks 

M-NET address 
setting 

 

 

 

The default value is 0.

 

IP address setting 

   

(simple setting) 

 

 

The settings of the simple 
setting have the priority 
over other settings. 

Function selection 

 

 

 

Presence/absence of   
K transmission converter 
connection, local operation 
prohibition setting, and external
input mode 

Group registration 

 

 

 

 

Registration of 
interlocked 
operation with the 
Lossnay unit 

 

 

 

 
 

Switch for start-up 
mode

 

 

 

 

 
 

Other settings 

 

 

 

Available functions vary 
depending on the tools. 

 

1) How to set the IP address with dipswitches 

IP addresses between 192.168.1.1 and15 can be set using the 4-pin dip switch on SW2. 
Set this switch before turning the power on. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

Note 

 When setting IP addresses with the Initial Setting Web or the Initial Setting Tool, set all four 

dipswitches on SW2 to OFF.

 

1

2

3

4

Contents (IP address) 

OFF OFF OFF OFF

Address that is set with Initial Setting Web or 
Initial Setting Tool. 
(Initial IP address setting is 192.168.1.1) 

OFF OFF OFF ON Starts from 192.168.1.1   
OFF OFF ON OFF Starts from 192.168.1.2   
OFF OFF ON

ON Starts from 192.168.1.3 

OFF ON OFF OFF Starts from 192.168.1.4 
OFF ON OFF ON Starts from 192.168.1.5 
OFF ON

ON OFF Starts from 192.168.1.6 

OFF ON

ON

ON Starts from 192.168.1.7 

ON OFF OFF OFF Starts from 192.168.1.8 
ON OFF OFF ON Starts from 192.168.1.9 
ON OFF ON OFF Starts from 192.168.1.10 
ON OFF ON

ON Starts from 192.168.1.11 

ON ON OFF OFF Starts from 192.168.1.12 
ON ON OFF ON Starts from 192.168.1.13 
ON ON

ON OFF Starts from 192.168.1.14   

ON ON

ON

ON Starts from 192.168.1.15   

(Inside the cover) 

SW 2 

1  2  3  4 

ON 
OFF 

Содержание Central Controller GB-50A

Страница 1: ...el GB 50A Instruction Book Contents Before using the controller please read this Instruction Book carefully to ensure correct operation Store this Instruction Book in a location that is easy to find 1 Safety 1 2 Introduction 3 3 Function 4 4 External input output function 8 ...

Страница 2: ...curely install in a place which can withstand the weight of the controller If it is not enough the unit may fall and cause an injury Contact your dealer if the controller will not be used any more or will be scrapped Make sure that the controller is connected to a rated power supply If the controller is not connected to a rated power supply it may cause a fire or damage to the controller Do not re...

Страница 3: ...cified temperature range Observe the specified temperature range when operating the controller If the controller is used outside the specified temperature range it may cause serious damage Be sure to check the operation temperature range in the operation manual Do not touch the switch with wet hands It may cause an electric shock Do not use the controller for special applications This product is d...

Страница 4: ...B 50A IP address is 192 168 1 1 User Default user name Default password Managers administrator admin 2 Introduction Notes With the registration of GB 50A License Pack Web Monitor Annual Schedule Weekly Schedule Sending Error Mail and Maintenance Tool Advanced functions will be available Consult the dealer for information on other functions that require a license i e Charge Saving Energy Control As...

Страница 5: ...independent OA processing unit or LOSSNAY in one group 1 16 units Note Indoor unit independent OA processing unit and LOSSNAY can not register to the same group Number of remote controllers in one group 1 2 Number of system controllers in one group 0 4 including the number of remote controller in one group 0 3 for groups which have one remote controller Number of indoor units interlocked with one ...

Страница 6: ...nding on the model Start stop of interlocked equipment Lossnay Switching start Hi Lo stop collectively or for each group when connecting with interlocked equipment Lossnay However ventilation mode can not be selected for the interlocked equipment Prohibition of local control Selecting the items for which local control is prohibited collectively or for each group Items include start stop operation ...

Страница 7: ...ng the 4 pin dip switch on SW2 Set this switch before turning the power on Note When setting IP addresses with the Initial Setting Web or the Initial Setting Tool set all four dipswitches on SW2 to OFF 1 2 3 4 Contents IP address OFF OFF OFF OFF Address that is set with Initial Setting Web or Initial Setting Tool Initial IP address setting is 192 168 1 1 OFF OFF OFF ON Starts from 192 168 1 1 OFF ...

Страница 8: ...s for normal use ON OFF Setting is prohibited OFF ON Setting is prohibited ON ON Start up with the update mode The software can be updated with the normal mode If the update fails or the software does not work properly use this setting to update the software again SW1 3 and SW1 4 are always OFF Notes When 15 or fewer GB 50A units are used in the designated network for air conditioning it is recomm...

Страница 9: ...l remote controller s operation will be prohibit 3 Perform ON OFF operation with level signal Only the ON OFF operation of the central controller and the local remote controller will be prohibit 4 Perform ON OFF operation prohibit permit operation with pulse signal Set the pulse width while the contact is ON to 0 5 to 1 0 second Settings for these functions can be set with the Initial Setting Web ...

Страница 10: ... they must be manually turned back on When ON OFF input signal is selected the status will be changed from OFF to ON when the external input signal contact turns OFF to ON B Pulse signal Even if the ON signal is input during ON the status will remain at the ON status When the local remote controller is prohibited the ON OFF operation operation mode selection and temperature setting from the local ...

Страница 11: ...10 ...

Страница 12: ...11 ...

Отзывы: