6 Parameter Setting
6.1 CC-Link IE Field Network Parameter Setting
45
6
6
Parameter Setting
This chapter describes the procedure for setting parameters of the IO-Link module.
6.1
CC-Link IE Field Network Parameter Setting
Setting via the engineering tool
Set the parameter of the IO-Link module with the network parameter written to the CPU module of the CC-Link IE Field
Network master station. For details on setting the CC-Link IE Field Network master station, refer to the following.
User's manual for the master/local module used
Setting procedure
1.
Open the "CC IE Field Configuration" window.
For the master/local module RJ71GF11-T2
[Navigation window]
[Parameter]
[Module Information]
[RJ71GF11-T2]
[Module Parameter]
[Basic Settings]
[Network Configuration Settings]
2.
Select an IO-Link module from "Module List", and drag and drop it to the list of stations or the network map.
3.
Configure the IO-Link module settings.
*1 Note that necessary points vary depending on the connected IO-Link device.
For details, refer to the manual of the IO-Link device.
(1) List of stations
(2) Network map
Item
Description
STA#
Set the station number of a slave station to be connected to the network.
The station number need not be a serial number. (Must not be overlapped.)
Station Type
Set "Intelligent Device Station".
RX/RY Setting
Set RX and RY assignment. For IO-Link modules, set 80 points or more.
RWw/RWr Setting
Set RWw and RWr assignment in units of four points. For IO-Link modules, this setting should be
determined by the functions used.
• IO-Link mode: 4 to 132 points (IO-Link module main: 4 points, process data: 0 to 128 points)
• SIO mode: 4 points
Reserved/Error Invalid Station/System Switching
Monitoring Target Station
Use this to set the slave station as an error invalid station or a switching monitoring target station.
(1)
(2)
Содержание CC-Link IE Field NZ2GF12A-60IOLH8
Страница 1: ...CC Link IE Field Network Waterproof Remote IO Link Module User s Manual NZ2GF12A 60IOLH8 ...
Страница 2: ......
Страница 30: ...28 3 PROCEDURES BEFORE OPERATION MEMO ...
Страница 100: ...98 8 MODULE FUNCTION BLOCKS MEMO ...
Страница 109: ...9 PROGRAMMING 9 2 Program Example of Setting Parameters Using a Dedicated Instruction 107 9 ...
Страница 116: ...114 9 PROGRAMMING 9 3 Example of Program to Communicate with an IO Link Device ...
Страница 118: ...116 10 MAINTENANCE AND INSPECTION MEMO ...
Страница 155: ...APPX Appendix 7 Additional or Changed Functions 153 A MEMO ...
Страница 157: ...I 155 MEMO ...
Страница 161: ......