12
TERMS
Unless otherwise specified, this manual uses the following terms.
Term
Description
CC-Link IE Field Network
A high-speed and large-capacity open field network that is based on Ethernet (1000BASE-T)
CommDTM (Communication DTM)
A software module used to configure the communication setting required for communications between a personal
computer and field devices via the IO-Link master.
CPU module
A generic term for the MELSEC iQ-R series CPU module, MELSEC-Q series CPU module, and MELSEC-L series CPU
module
Cyclic transmission
A function by which data are periodically exchanged among stations on the same network using link devices (RX, RY,
RWw, and RWr)
Data link
A generic term for cyclic transmission and transient transmission
Dedicated instruction
An instruction that simplifies programming for using functions of intelligent function modules
Device DTM
A software module used to configure the parameter settings of field devices or monitor field devices.
Disconnection
A process of stopping data link if a data link error occurs
DTM (Device Type Manager)
A software module used to configure the communication settings, set parameters of field devices, or monitor field
devices when an FDT frame application is used.
DTM catalog
By registering the M_CommDTM-IOLink, the communication settings are automatically configured, and the list of
available DTMs is displayed.
Engineering tool
Another term for the software package for the MELSEC programmable controllers
FDC
An abbreviation for the MELSOFT FieldDeviceConfigurator
FDT (Field Device Tool)
Software standard specifications for management, maintenance, adjustment, and development of field devices
FDT frame application
A generic term for applications to use a DTM. An FDT frame application complies with the FDT/DTM open standard
Global label
A label that is valid for all the program data when multiple program data are created in the project. The global label has
two types: a module specific label (module label), which is generated automatically by GX Works3, and an optional label,
which can be created for any specified device.
Intelligent device station
A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic transmission. This
station can perform transient transmission as well. This station responds to a transient transmission request from
another station and also issues a transient transmission request to another station.
IO-Link device
An external device that supports IO-Link
IO-Link module
An abbreviation for the CC-Link IE Field Network waterproof remote IO-Link module
IODD (IO-Link Device Description)
This description consists of the XML file containing the IO-Link device information and the image file in the png format.
This description is supplied from a manufacturer of an IO-Link device.
IODD DTM Configurator
A software program that operates the IODD file (device description file of IO-Link) as the Device DTM.
ISDU
Data read from or written to parameters of IO-Link devices
Label
A label that represents a device in a given character string
Link device
A device (RX, RY, RWr, or RWw) in a module on CC-Link IE Field Network
Link special register (SW)
Word data that indicates the operating status and data link status of a module on CC-Link IE Field Network
Link special relay (SB)
Bit data that indicates the operating status and data link status of a module on CC-Link IE Field Network
Local station
A station that performs cyclic transmission and transient transmission with the master station and other local stations.
The station is controlled by programs in the CPU module or other equivalent modules on the station.
M_CommDTM-IOLink
CommDTM that supports communications with the IO-Link device via the IO-Link module.
Master station
A station that controls the entire network. This station can perform cyclic transmission and transient transmission with all
stations. Only one master station can be used in a network.
Master/local module
An abbreviation for the CC-Link IE Field Network master/local module
MELSOFT FieldDeviceConfigurator
Configuration Tool, which is developed by Mitsubishi Electric Corporation. MELSOFT FieldDeviceConfigurator complies
with the FDT/DTM open standard and is used for parameter settings, maintenance, and adjustment of field devices as
an FDT frame application.
Module label
A label that represents one of memory areas (I/O signals and buffer memory areas) specific to each module in a given
character string.
For the module used, GX Works3 automatically generates this label, which can be used as a global label.
Remote device station
A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic transmission. This
station responds to a transient transmission request from another station.
Remote I/O station
A station that exchanges I/O signals (bit data) with the master station by cyclic transmission
Remote input (RX)
Bit data input from a slave station to the master station (For some areas in a local station, data are input in the opposite
direction.)
User's manual for the master/local module used
Содержание CC-Link IE Field NZ2GF12A-60IOLH8
Страница 1: ...CC Link IE Field Network Waterproof Remote IO Link Module User s Manual NZ2GF12A 60IOLH8 ...
Страница 2: ......
Страница 30: ...28 3 PROCEDURES BEFORE OPERATION MEMO ...
Страница 100: ...98 8 MODULE FUNCTION BLOCKS MEMO ...
Страница 109: ...9 PROGRAMMING 9 2 Program Example of Setting Parameters Using a Dedicated Instruction 107 9 ...
Страница 116: ...114 9 PROGRAMMING 9 3 Example of Program to Communicate with an IO Link Device ...
Страница 118: ...116 10 MAINTENANCE AND INSPECTION MEMO ...
Страница 155: ...APPX Appendix 7 Additional or Changed Functions 153 A MEMO ...
Страница 157: ...I 155 MEMO ...
Страница 161: ......