1.3 Abbreviated names, generic names and terms
Abbreviated names, generic names and terms Description
Abbreviated names,
generic names and terms
Description
AJ65BT-RPI-10A/10B
Abbreviation of AJ65BT-RPI-10A/AJ65BT-RPI-10B type CC-Link
system space optical repeater module
AJ65SBT-RPT
Abbreviation of AJ65SBT-RPT type CC-Link system repeater (T-
junction) module.
AJ65SBT-RPS/RPG
Abbreviation of AJ65SBTRPS/AJ65SBT-RPG type CC-Link system
optical repeater module.
AJ65FBTA-RPH
Abbreviation of AJ65FBTA-RPH type CC-Link system low profile
waterproof type repeater hub module.
AJ65BTS-RPH
Abbreviation of AJ65BTS-RPH type CC-Link system spring clamp
terminal block type repeater hub module.
A module
Abbreviation of AJ65BT-RPI-10A type CC-Link system space
optical repeater module
B module
Abbreviation of AJ65BT-RPI-10B type CC-Link system space
optical repeater module
Segment
System between terminating resistances connected to each other
through cross-over cables.The conventional CC-Link system can
be said to be configured with one segment (Refer to Section 2.1.).
Master station
Station to control the data link system. One station is required for
each system.
Local station
Station which has a sequencer CPU and can communicate with the
master station and the other local stations.
Remote I/O station
Remote station processing only information in unit of bit.
(AJ65BTB1-16D, AJ65SBTB1-16D, AJ65SBTB1-8
, etc.)
Remote device station
Remote station processing only information in unit of bit and in unit
of word.(AJ65BT-64AD, AJ65BT-64DAV, AJ65BT-64DAI, etc.)
Remote station
Generic name of remote I/O station and remote device station.
Controlled by the master station.
Intelligent device station
Station allowing transient transmission such as AJ65BT-R2.
(Including local stations)
Repeater
Module for expanding the CC-Link system by connecting the
segments to each other.
Ready master station
Backup station which inherits data link control when the master
station comes off parallel due to error.
Built-in CC-Link function
Abbreviation of built-in CC-Link system master/local functions of the
L26CPU-BT and L26CPU-PBT
Master local module
Generic name of RJ61BT11, QJ61BT11N, QJ61BT11, built-in CC-
Link function, AJ61BT11, A1SJ61BT11, AJ61QBT11, and
A1SJ61QBT11
Master module
Generic name of the master local module that is used as a master
station
Local module
Generic name of the master local module that is used as a local
station
Remote module
Generic name of AJ65BTB1-16D, AJ65SBTB1-16D,
AJ65BT-64AD, AJ65BT-64DAV, AJ65BT-64DAI and A852GOT.
Intelligent device module Module allowing transient transmission such as AJ65BT-R2.