Application examples
203
10
∗1
Adjustment parameter for adjusting the setting of another parameter.
∗2
The parameter number in parentheses is the one for use with the LCD operation panel and the parameter unit.
1246
Line speed at winding diameter
calculated value activation
1 m/min
1 m/min
1247
Winding diameter change
increment amount limit
9999
0.2 mm
Setting
Pr.1247
= "9999 (initial value)" disables the roll diameter
calculation.
Be sure to change the setting from the initial value for the roll
diameter calculation.
1249
Number of averaging for
winding diameter calculation
4
4
Use this parameter to enable the primary delay filter relative to
the result of the roll diameter calculation.
1251
Winding diameter
compensation speed filter time
constant
0 s
0.1 s
1252
Dancer lower limit position
400%
500%
1253
Initial winding diameter
calculation deadband
1.0%
10%
1254
Initial winding diameter
calculation deadband 2
9999
0%
Use this parameter to prevent the dancer roll from moving too
much when the normal operation starts after the initial roll
diameter calculation is completed.
1255
Accumulated amount
9999
270 mm
The setting value can be calculated from the setting of
Pr.1253
Initial winding diameter calculation deadband
(10%)
and the
accumulated amount (300 mm) as follows: 300 mm × 0.9 = 270
mm
1258
Integral term limit at start
2.5%
1.5%
Use these parameters to adjust winding speed for the initial roll
diameter calculation.
1259
PID term limit at start
2.5%
1.5%
1285
Taper setting analog input
selection
9999
4
4: The taper ratio is input through terminal 4.
1286
Winding diameter at taper start
9999
800 mm
1287
Taper ratio setting
0%
9999
9999: The taper ratio is set through the analog input terminal.
Pr.
Parameter name
Initial
value
Setting
value
Remarks