INVERTER INSTALLATION AND PRECAUTIONS
3
1
INVERTER INSTALLATION AND PRECAUTIONS
Inverter model
Specification differs by the type. Major differences are shown in the table below.
Conforming to IEC 60721-3-3 3C2/3S2
Applicable for the FR-A820-00340(5.5K) or higher, and the FR-A840-00170(5.5K) or higher.
NOTE
• In this Instruction Manual, the inverter model name consists of the applicable motor capacity and the rated current. (Example) FR-A820-00046(0.4K)
Inverter placement
Installation environment
Before installation, confirm that the following environment conditions are met.
Temperature applicable for a short time, e.g. in transit.
For the installation at an altitude above 1000 m, consider a 3% reduction in the rated current per 500 m increase in altitude.
2.9 m/s
2
or less for the FR-A840-04320(160K) or higher.
Surrounding air temperature is a temperature measured at a measurement position in an enclosure.
Ambient temperature is a temperature outside an enclosure.
For the amount of heat generated by the inverter unit, refer to the Instruction Manual (Detailed).
Type
Monitor output
Initial setting
Built-in
EMC filter
Control logic
Rated
frequency
Pr.19 Base frequency voltage
FM
(terminal FM equipped model)
Terminal FM: pulse train output
Terminal AM: analog voltage output (0 to
10 VDC)
OFF
Sink logic
60 Hz
9999
(same as the power supply voltage)
CA
(terminal CA equipped model)
Terminal CA: analog current output (0 to 20 mADC)
Terminal AM: analog voltage output (0 to
10 VDC)
ON
Source logic
50 Hz
8888
(95% of the power supply voltage)
Installation on the enclosure
• Install the inverter on a strong surface securely with screws.
• Leave enough clearances and take cooling measures.
• Avoid places where the inverter is subjected to direct sunlight, high temperature and high humidity.
• Install the inverter on a nonflammable wall surface.
• When encasing multiple inverters, install them in parallel as a cooling measure.
• When designing or building an enclosure for the inverter, carefully consider influencing factors such as heat generation
of the contained devices and the operating environment.
For the FR-A820-00250(3.7K) or lower and FR-A840-00126(3.7K) or lower, allow 1 cm or more clearance.
When using the FR-A820-01250(22K) or lower and FR-A840-00620(22K) or lower at the surrounding air temperature of
40°C or less (30°C or less for the SLD rated inverter), side-by-side installation (0 cm clearance) is available.
There needs to be a space of at least 30 cm in front of the inverter to replace the cooling fan of the FR-A840-04320(160K)
or higher.
Refer to the Instruction Manual (Detailed) for fan replacement.
Item
Description
Surrounding air
temperature
LD, ND (initial setting), HD
-10 to +50°C (non-freezing)
Enclosure
SLD
-10 to +40°C (non-freezing)
Ambient humidity
With circuit board coating (conforming to IEC 60721-3-3 3C2/3S2): 95% RH or less (non-
condensing),
Without circuit board coating: 90% RH or less (non-condensing)
Storage temperature
-20 to +65°C
Atmosphere
Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Altitude
2500 m or lower
Vibration
5.9 m/s
or less at 10 to 55 Hz (directions of X, Y, Z axes)
FR -
-
A8 0
2
-
-
1
GN
00046
400 V class
Symbol Voltage class
200 V class
4
2
CA
Symbol Type
FM
2
1
Symbol
Description
0.4 to 280K
Inverter ND rated capacity (kW)
00023 to 06830
Inverter SLD rated current (A)
Symbol
Function
GN
CC-Link IE TSN functionality
Symbol Circuit board coating
Without
None
With
With
Plated conductor
Without
With
Without
06
60
Capacity plate
Inverter model
Serial number
Rating plate
FR-A820-00046-1-GN
Input rating
Output rating
SERIAL
Inverter model
,1387;;;;;
02'(/)5$*1
287387;;;;;
6(5,$/;;;;;;;;;
0$'(,1;;;;;
Country of origin
Fix six positions for the FR-A840-04320(160K) or higher.
Clearances (side)
Inverter
Clearances (front)
10 cm
or more
10 cm
or more
10 cm
or more
10 cm
or more
20 cm
or more
20 cm
or more
5 cm
or more
∗1,∗2
5 cm
or more
∗1,∗2
FR-A820-03160(55K) or lower,
FR-A840-01800(55K) or lower
FR-A820-03800(75K) or higher,
FR-A840-02160(75K) or higher
Vertical
5 cm
or more
∗1,∗3
Allow clearance.
Measurement
position
Measurement
position
Inverter
5 cm
5 cm
5 cm