315
Setting from the parameter unit, operation panel
4
4.23 Setting from the parameter unit, operation panel
4.23.1 PU display language selection (Pr. 145)
* Depending on the parameter unit, some parameter names or fault names etc. may not be displayed at all, or only displayed in English.
The above parameters can be set when
Pr. 160
User group read selection
= "0".
(Refer to page 190.)
4.23.2 Setting dial potentiometer mode/key lock selection (Pr. 161)
The above parameters can be set when
Pr. 160 User group read selection
= "0".
(Refer to page 190.)
Purpose
Parameter that must be Set
Refer to
Page
Switch the display language of the
parameter unit
PU display language
selection
Pr. 145
Use the setting dial of the operation
panel like a potentiometer for frequency
setting.
Key lock of operation panel
Operation panel operation
selection
Pr. 161
Control of the parameter unit, operation
panel buzzer
PU buzzer control
Pr. 990
Adjust the LCD contrast of the parameter
unit
PU contrast adjustment
Pr. 991
The display language of the parameter unit (FR-PU04/FR-PU07) can be changed to other languages.
Parameter
Number
Name
Initial Value
Setting Range
Definition *
145
PU display language selection
1
0
Japanese
1
English
2
Germany
3
French
4
Spanish
5
Italian
6
Swedish
7
Finnish
The setting dial of the operation panel (FR-DU07) can be used like a potentiometer to perform operation.
The key operation of the operation panel can be disabled.
Parameter
Number
Name
Initial Value
Setting
Range
Description
161
Frequency setting/key lock
operation selection
0
0
Setting dial frequency
setting mode
Key lock invalid
1
Setting dial potentiometer
mode
10
Setting dial frequency
setting mode
Key lock valid
11
Setting dial potentiometer
mode