30
2 SPECIFICATIONS
2.7 Built-in Analog Specifications
2.7
Built-in Analog Specifications
The analog input/output specifications of the built-in analog function are explained below.
For details on the analog built-in function, refer to
MELSEC iQ-F FX5 User's Manual (Analog Control - CPU module built-
in, Expansion adapter).
Analog input
*1 Products manufactured before June 2016 do not adapt to this specification.
*2 "Digit" refers to digital values.
Analog output
*1 There is a dead band near 0 V output, which is an area where some analog output values do not reflect digital input values.
*2 External load resistance is set to 2 k
Ω
when shipped from the factory. Thus, output voltage will increase somewhat if the resistance is
set higher than 2 k
Ω
. When the resistance is 1 M
Ω
, output voltage increases maximum 2%.
*3 Products manufactured before June 2016 do not adapt to this specification.
*4 "Digit" refers to digital values.
Item
Specifications
Analog input points
2 points (2 channels)
Analog input
Voltage
0 to 10 V DC (input resistance 115.7 k
Ω
)
Digital output
Unsigned 12-bit binary
Device allocation
SD6020 (Input data of ch1)
SD6060 (Input data of ch2)
I/O characteristics, Maximum resolution
Digital output value
0 to 4000
Maximum resolution
2.5 mV
Accuracy
(Accuracy for the full scale of the digital
output value)
Ambient temperature
25
±
5
Within
±
0.5% (
±
20 digit
Ambient temperature
0 to 55
Within
±
1.0% (
±
40 digit
Ambient temperature
-20 to 0
Within
±
1.5% (
±
60 digit
Conversion speed
30
μ
s /channels (data refreshed every operation cycle)
Absolute maximum input
-0.5 V, +15 V
Insulation method
Inside the CPU module and the analog input circuit are not insulated. Between input
terminals (channels) is not insulated.
Occupied points
0 points (does not pertain to the max. No. of input/output points of the CPU module.)
Terminal block used
European-type terminal block
Item
Specifications
Analog output points
1 points (1 channels)
Digital input
Unsigned 12-bit binary
Analog output
Voltage
0 to 10 V DC (external load resistance 2 k to 1 M
Ω
)
Device allocation
SD6180 (Output setting data of ch1)
I/O characteristics, Maximum resolution
Digital input value
0 to 4000
Maximum resolution
2.5 mV
Accuracy
(Accuracy for the full scale of the analog
output value)
Ambient temperature
25
±
5
Within
±
0.5% (
±
20 digit
)
Ambient temperature
0 to 55
Within
±
1.0% (
±
40 digit
)
Ambient temperature
-20 to 0
Within
±
1.5% (
±
60 digit
)
Conversion speed
30
μ
s (data refreshed every operation cycle)
Insulation method
Inside the CPU module and the analog output circuit are not insulated.
Occupied points
0 points (does not pertain to the max. No. of input/output points of the CPU module.)