Installation
103
Mitel SMB Controller
syd-0657/2.0 – R6.0 – 09.2018
Note
The arrows on the wiring adapters specify the plug-in orientation of the required port assign-
ment.
4. 5. 3
Fitting DSP modules
DSP modules belong to the category of system modules and are fitted to the DSP slot
(see Fig. 7). Three DSP modules are stackable.
1. Shut down the communication server (see "Shut-down mode", page 201) and dis-
connect it from the power supply.
2. Remove the housing cover.
3. Remove the fastening screw from the DSP module slot.
4. Instead of the fastening screw, screw in the spacer sleeve enclosed with the mod-
ule.
5. Place the module on the DSP slot (or onto a module already fitted in that slot) and
press down evenly on both connectors as far as the stop.
WA-1PRI
TIC-1PRI
–
PRI
Test
4)
–
–
TIC-1PRI-T1
5)
–
PRI
Test
–
–
WA-8DSI
8DSI
–
4 x DSI
6)
4 x DSI
7)
1 x DSI
(port 7)
1 x DSI
(port 8)
–
–
–
1) The wiring adapter is not part of the equipment supplied with this interface card and must be ordered sepa-
rately.
2) Must not be used in USA/Canada.
3) Not yet supported with Release 6.0
4) For test purposes the PRI interface is also routed in parallel to port X.2.
5) Must only be used in USA/Canada.
6) Port 7 is also routed to X.3
7) Port 8 is also routed to X.4
CAUTION
!
Be sure to observe the "Safety regulations", page 89.
Wiring adapter
Interface card
Plug-in ori-
entation
Port number
X.1
X.2
X.3
X.4
WA-8DSI