116
Inter-Tel
®
Attendant Console User Guide
Waiting for
response from
telephone sys-
tem
In an Axxess system, the Axel
Office Server unable to com-
municate with telephone sys-
tem
Verify the hardware cables between the Axel
Office Server and the Axxess system are prop-
erly attached.
Verify the system is using the proper serial
cable (part number 813.1682) and modular
adapter (part number 804.2545). These parts
are available in the System OAI PC Connection
Kit (part number 828.1427) or the Universal
RS232 Kit (part number 828.1282).
Verify the Axel Office Server is configured with
the same baud rate as the telephone system
serial port.
Verify the telephone system serial port is config-
ured for Level 2 System OAI.
Verify the telephone system serial port is config-
ured for hardware flow control and auto baud is
disabled.
CT Server, Switch Transceiver
(Axxess only), CPC, Call Pro-
cessing Server in an Axxess
system, or the CS-5200/5400/
5600 in the Inter-Tel 5000 sys-
tem not responding
Restart the server.
The server
closed the con-
nection
In an Axxess system, the Axel
Office Server is already in use
by another application
Only one application can use a serial port. Ver-
ify the console is connecting to the correct TCP
port. To do so, select
Options
from the Console
drop-down menu. The Connection tab shows
the TCP port.
If the TCP port is correct, determine what IP
address is already using the Axel Office Server.
To do this, telnet to the Axel Office Server's con-
figuration port: “telnet <axel_ip_addr> 4096".
Select
Connections
from the Tools Setup
menu.
ERROR
POSSIBLE PROBLEM
FIX
Содержание Inter-Tel
Страница 1: ...User Guide Inter Tel Attendant Console M I T E L ...
Страница 2: ......
Страница 6: ...4 NOTES ...
Страница 8: ......
Страница 14: ......
Страница 124: ......
Страница 144: ......
Страница 149: ......
Страница 150: ...Part No 835 2270 Issue 3 1 April 2008 A946 3381A ...