      WIRE VERSION IR BARRIER 

   BLACK VERSION – MAXIMUM RANGE 15 METRES 

    WHITE VERSION – MAXIMUM RANGE 3,5 METRES 

     Installation and Use Manual – English 

 

1.  Detach the caps and remove the extruded cover.  

2.  Drill both ends of the aluminium profile and fix it to the wall. Additional holes may be required for longer 

barriers.  Once  the  aluminium  profile  and/or  the  upper  and  lower  plugging  caps  have  been  drilled,  we 
recommend sealing the holes with silicone sealant 

3.  CONNECTIONS:  Use  shielded  cables  and  connect  one  extremity  of  the  shield  to  the  mains 

grounding system and the other extremity to the negative logic of the power supply of the barrier 
RX  12Vcc+  (GND-).  
If  the  system  masses  are  not  equipotential,  connect  the  shield  only  on  the  central 
side.In addition to the standard connections for the power supply, tamper function and alarm contact, it is 
also  necessary  to  connect  the  Winner  TX  transmitter  to  the    Winner  RX  receiver  using  the  two 
synchronism  wires  called +Sinc TX  and  –Sinc  RX (connect  +Sinc TX  to  +Sinc RX and  –Sinc  TX  to 
Sinc RX
). 

4.  Power the system with 13.8 Vdc and verify that the LEDs Led SYNC on both the Winner TX and Winner 

RX circuits start to flash. Otherwise, check that the synchronism wires have been correctly connected. 

5.  Place the jumper in position OR and test the barrier by individually obstructing the adjacent pairs of LEDs 

that form the beam. Verify that Led ALARM switches on. 

6.  After  completing  the  test,  program  the  desired  operating  mode,  OR  /  AND  (FAST,  for  indoor 

installations only) and close the barriers. 

• Energy consumption of the TX and RX motherboards: 40 mA 
• Energy consumption of the additional TX and RX modules: 8 mA 
• Protection class: IP54 
• Triggering time: 50 or 500 msec (alarm period about 2 sec) 
• Operating mode: AND OR 
• N.C. alarm contact: 0.5 A 30 VDC, 0.25 A 60 VDC 

 

WARNINGS: 

 

 

Power the device using the 13.8 Vdc stabilised voltage only (Winner work from 11.5V to  15V, 
but we suggest not less than 12 V, best 13.8V) 

 

Install the additional modules in the correct direction (as shown in the following figure). 

 

Do not insert the additional RX modules into the TX barrier and the additional TX modules into 
the RX barrier. 

 

Avoid routing the connection cables in raceways where power leads are present. 

 

Do not install outdoors, in the open air, without a suitable covering. 

 

MITECH  shall  not  answer  for  any  barrier  damage  and/or  malfunction  caused  by  incorrect 
installation and/or improper use of same. 

 

 

 

 

 

 

 

 