Pole installation
1. Position the main bracket at a height between 80 and 90 cm from the ground and make
a hole in the pole, maximum diameter 10/12 mm (figure 1).
2. Position the MICRO PL bracket at the back of the pole and use the four M4x70 screws
and the supplied washers to fix the two brackets (figures 1 and 2). Make sure that the
pole cable exit hole is aligned with that of the bracket.
3. Screw the flanged M16 nut and tighten it with a 16 mm wrench (figure 2).
4. Insert the following components (figures 3 and 4):
- the main structure where the RX or TX antenna is connected
- the serrated washer
- the M16 nut tightening it with a 16 mm wrench
5. Insert the cables and make the connections (see pages 11 and 12).
Note: the tamper signal can be taken by connecting it directly to the microswitch, or by
connecting the microswitch to the TAMPER IN input of the antenna and then picking up
the signal from the TAMPER OUT output.
6. Align the antennas (see installation procedure on pages 13 and 14).
7. Insert the following components (figure 5):
- polycarbonate cover
- closing cap by tightening it with the M4 screw
- Screw cover cap