MITECH GEMINI Series Скачать руководство пользователя страница 4

MITECH

®

 srl 

Offices: 

Via Roncaglia, 14 
20146 Milano 

– Italia 

Production: 

Via Ramazzone, 23 
43010 Fontevivo (PR) 

– Italia   

Phone: +39 02.48006383 
Fax: +39 02.48025620 
[email protected] 

www.mitech-security.com 

MADE IN ITALY 

GEMINI - Rev. 05 - 01/2020 - MITECH srl reserves the right to change the information in this document without warning. 

Page 2 of 2 

INSTALLATION: 

1. 
2. 
 
 
 
 
 
 
 

 

3. 
 
 
 
 
 
 
 
 
 
 

 

4. 
 

Position all dip switches on OFF both the receiver and the transmitter and power supply the barriers. 
Use this procedure to set the frequency: 

 

A)

 Both on RX profile and on TX profile, use dip switches 1, 2 and 3 

to define the frequency, see table (available 8 frequencies) 

 

B)

 To confirm the frequency both on RX profile and on TX profile, 

position the dip switch 7 on ON 

 

C)

 Once the frequency is set, return the dip switch 7, 

on both profiles on OFF 

 

Orient the receiver's optical unit in the direction of the transmitter and vice versa until the red LED on the receiver is turned off and the 
maximum voltage is read on the display. For vertical adjustments, act on the adjusting screw, while for horizontal adjustments turn the 
bracket (see IMAGE 1). If necessary, help with the viewfinder (see IMAGE 2). 

 
 
 
 
 
 
 
 
 

 

Turn the trimmer                                   on the right side of the receiver to adjust the sensitivity. 

VIEWFINDER POINT OF VIEW

 

IMAGE 2 

IMAGE 1 

FUNCTION TABLE: 

NOTE: The signal level is only visible on the RX profile 

NOTES FOR INSTALLATION: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

FREQUENCY NUMBER (FROM 1 TO 8) 

DI

P

 

OFF   ON    OFF   ON    OFF   ON    OFF   ON 
 
OFF   OFF   ON    ON    OFF   OFF   ON    ON 
 
OFF   OFF   OFF   OFF   ON    ON    ON    ON 

GEMINI 30 
GEMINI 60 
GEMINI 100 

WARNING: 

Once the frequency is set, do not leave the dip switch 7 in ON and the dip switch 8 in OFF, 

but bring the dip switch 8 in ON (signal level display mode). 

 

If you want from this setting see the frequency set, do the following: 

set the dip switch 7 in OFF and only after also the dip switch 8, not the reverse. 

 

If you want to return to signal level display mode (7 and 8 in ON), do the following: 

set the dip switch 8 in ON and only after also the dip switch 7, not the reverse. 

Adjusting screw 

Adjustable bracket 

FUNCTION 

AVOID IMPEDIMENTS 

AVOID DIRECT SUNLIGHT 

AVOID 
INSTALLABLE 
SURFACE 

AVOID THAT A RECEIVER CAN 
SEE MORE TRANSMITTERS 

DISTANCE OF DETECTION 

DISTANCE OF DETECTION 

ITEM 

RAY 
DISPERSION 
DIAMETER 

RAY DISPERSION DIAMETER 

EX

A

MP
LE

 

 O

F I

N

ST

A

LL

A

TIO

N

 H

EI

G

H

SIGNAL 

LEVEL 

FREQUENCY 

SETTING 

NOT 

USED 

FREQUENCY 

DISPLAY 

MIN 

MAX 

Содержание GEMINI Series

Страница 1: ...ifica quando la potenza del segnale diminuisce lentamente fino a 0 8 V il rilevatore attiva l allarme anti flog uscita fault quando il segnale scende a 0 4 V allarme attivo MADE IN ITALY GEMINI Rev 05 01 2020 MITECH srl si riserva di modificare i dati senza preavviso Pagina 1 di 2 GEMINI è la mini barriera all infrarosso attivo a doppia lente dalle dimensioni molto contenute Precablata e pronta pe...

Страница 2: ...ione possibile Per le regolazioni verticali agire sulla vite di regolazione mentre per quelle orizzontali intervenire ruotando la staffa vedere IMMAGINE 1 Se necessario aiutarsi con il mirino vedere IMMAGINE 2 Ruotare il trimmer posizionato su lato destro del ricevitore per regolare la sensibilità PUNTO DI OSSERVAZIONE DEL MIRINO porsi ad almeno 5 cm di distanza dal foro che è presente sia sull RX...

Страница 3: ... IP55 IP65 with box TOWER GARDEN Anti flog function where signal strenght decrease slowly to 0 8 V the detector will active anti flog alarm fault output when signal decrease ti 0 4 V will active alarm MADE IN ITALY GEMINI Rev 05 01 2020 MITECH srl reserves the right to change the information in this document without warning Page 1 of 2 GEMINI is the mini IR barrier with dual lens with and small di...

Страница 4: ... turn the bracket see IMAGE 1 If necessary help with the viewfinder see IMAGE 2 Turn the trimmer on the right side of the receiver to adjust the sensitivity VIEWFINDER POINT OF VIEW IMAGE 2 IMAGE 1 FUNCTION TABLE NOTE The signal level is only visible on the RX profile NOTES FOR INSTALLATION FREQUENCY NUMBER FROM 1 TO 8 DIP OFF ON OFF ON OFF ON OFF ON OFF OFF ON ON OFF OFF ON ON OFF OFF OFF OFF ON ...