GEMINI
ACTIVE INFRARED MINI BARRIER WITH DOUBLE LENS, DISPLAY
AND 8 DIGITAL FREQUENCIES
Available in three versions GEMINI 30, GEMINI 60 et GEMINI 100
Installation and user manual
MADE IN ITALY
GEMINI - Rev. 08 - 03/2022 - MITECH srl reserves the right to change the information in this document without warning.
Page 1 of 2
GENERAL FEATURES
Maximum range: 30 m -
GEMINI 30
, 60 m -
GEMINI 60
, 100 m -
GEMINI 100
Minimum range: 15 m -
GEMINI 30
, 30 m -
GEMINI 60
, 50 m -
GEMINI 100
8 digital frequencies
Optical synchronization
Aligning with the viewfinder
Vertical detection angle: 20 °
Horizontal detection angle: 180 °
Operating temperature from -25 ° C to + 55 ° C
Buzzer alarm
Alarm signal threshold: 0.5 Volt
Power supply 13.8 – 24 Vdc
Maximum absorption 100 mA
Dimensions: 170x80x80 cm
Protection class: IP55
DESCRIPTION OF TERMINAL BLOCK, DISPLAY AND COMMANDS OF RECEIVER BARRIER
DESCRIPTION OF TERMINAL BLOCK, DISPLAY AND COMMANDS OF TRANSMITTER BARRIER
TAMP
TAMP
NC
COM
NO
VIN
GND
HEAT
HEAT
: not used
GND
: - Vdc (from 12 to 24 Vdc)
VIN
: + Vdc (from 12 to 24 Vdc)
NO
/
COM
/
NC
: alarm output NC or NO
TAMP
/
TAMP
: tamper output NC
LEVEL
GOOD
ALARM
SET
GREEN LED:
on = correct operation
off = alarm status
RED LED:
on = alarm status
off = correct operation
Menu entry
command
to modify settings
Commands
for changing
settings
HEAT
: not used
GND
: - Vdc (from 12 to 24 Vdc)
VIN
: + Vdc (from 12 to 24 Vdc)
TAMP
/
TAMP
: tamper output NC
INSTALLATION - SIGNAL LEVEL CHECK / ALIGNMENT - CHANGE PARAMETERS
INSTALLATION
Fix the barriers so that they are aligned using
the accessories supplied (template for fixing to the wall,
brackets for pole fixing, screws and rubber caps waterproof),
wire the terminal blocks and power the modules.
SIGNAL LEVEL CHECK / ALIGNMENT
88
Frequency setting command
1
2
3
4
The signal value is shown only on the display of the receiver profile.
The minimum operating value is 0.5 V, below this value the barrier is in alarm (RED LED
on and GREEN LED off).
To obtain the best signal, orient the optical unit of the receiver in the direction of the
transmitter and vice versa until the best possible value is obtained (the values are to be
considered optimal if greater than 3 V). For vertical adjustments, use the adjustment
screw, while for horizontal adjustments, turn the bracket.
If necessary, help yourself with the viewfinder.
Adjusting screw
Adjustment bracket
horizontal
Viewfinder
TAMP
TAMP
VIN
GND
HEAT
SET
The red LEDs indicate the set frequency
(see the table on page 2)
TEMPLATE
FOR WALL FIXING
BRACKET
FOR POLE FIXING