Page 34
Layer thickness too low
The measuring range depends on the selected reflector. If the
calculation gives a layer thickness less than the lower measuring range
of the reflector, this is displayed (s. Fig. 30). In this case, the setting
and the measurement should be considered critically:
-
Reflector set correctly?
-
Can measured value be expected within the measuring range of
reflector?
Please note:
If the measuring range has not been reached, a layer
thickness can still be determined by use of the MIT wheeled spacer.
The wheeled spacer increases the distance to the reflector, so that a
valid measurement result can be calculated.
Fig. 30 Display of too low
layer thickness result