85
4.Operation and Control method
4.1 Operation by the handy terminal
4.1.1 Initial screen
Connect handy terminal DT100(MISUMI Type: HDT100) and power on, display initial screen as
below(Continue Mode)in 5 seconds.
※Current position of all axes might be 0 when power on.
<Display operation mode>
Display each operation mode
C (CNT): Continue Mode(Stage drives during press arrow key)
S (STP): Step Mode(Stage drives constantly by pressing arrow key)
A (ABS): Absolute Mode(Stage drives to specified point by pressing arrow key)
O (ORG): Origin Mode(Start to origin return by pressing arrow key)
H (HOM): Home Mode(Stage drives to home position by pressing arrow key)
R: Remote Mode
※
”
R
”
(Remote Mode) displays only receive the command from external interface. Only accept
STOP key and JOG key.
<Axis>
Display axis that available controlled(No Link:XY、
Link Connecting(2units)
:XY,ZU、
Link Connecting
(3units)
:XY,ZU,VW)
。
<Code>
Display unit at the current point(No display
”
+
”
distance)
<Current point>
Display the current point( effective digit 8 digit, Except dot)
<Unit>
Set up by parameter. Display(p:pulse, u:μm, m:mm, d:deg, r:mrad)
<Status>
Display the axis condition
> : Machine limit +(CW)side is under detection
< : Machine limit -(CCW)side is under detection
■ : Machine limit both +(CW)and -(CCW)side are under detection(No connect to stage)
] : Software limit +(CW)side is under detection
[ : Software limit -(CCW)side is under detection
* : Machine origin point is under stop by origin return
H : Move to position and under stop by home position return
note)Machine limit display is came first when machine limit and soft limit are detected.
<Speed table number>
Display speed table No(0~9)
C X 1 2 3 4 5 6 7 8 p < 0
Y - 9 8 7 6 5 . 4 3 2 u > 1
Operation mode
Axis
Code
Current position
Status
Unit
Speed table number
Содержание DS102MS
Страница 166: ...166...