Fault Confirmation and Analysis

If problems persist after performing the tests below, please stop the air conditioner and 

contact our service centre nearest to you to get help.

Fault  

Fault analysis

Air conditioner does not operate at all. 

Is there a power failure

?

         

 

Is the unit unplugged

?

         

 

Is the power fuse or switch off

?

         

 

Is the timer set correctly

?

Remote controller does not display  

If the operation modes are changed too

any information. 

   frequently the remote controller may lose function.

           

 

If remote controller display is unclear or displays all  

           

 

symbols, please change the batteries or reset.  

           

 

Remove and replace batteries.

Cooling and heating efficiency is poor. 

Is the temperature set to the correct level

?

           

 

Are the filters clean

?

           

 

Are doors and windows closed

?

Indoor unit fan stops for about 10 minutes 

This is normal. The unit is defrosting the outdoor  

during heating. 

 

 unit coil. It should complete this process in about  

           

 

10 minutes at most. (Freezing occurs when  

 

           

 

outdoor temperature is low and humidity is high) 

You can hear the sound of running water 

This is the sound of expanding refrigerant inside  

           

 

the air conditioner.

           

 

Sound of accumulated water dropping on the    

           

 

heat-exchanger.

           

 

The sound of melting frost on heat-exchanger.

Performance Parameters

Model

MSS10 - 1HP

MSS15 - 1.5HP

indoor 

outdoor

indoor 

outdoor

Function

heat pump type

heat pump type

Power

230V~, 50Hz

230V~, 50Hz

Rated cooling/heating capacity (W)

2000/2400

3500/4000

Standard input power (W)

750(cool)/730(heat)

1300(cool)/1380(heat)

Standard input current (A)

3.5(cool)/3.4(heat)

6.2(cool)/6.6(heat)

Air flow volume (m³/h)

300

450

Dehumidifying  capacity (L/h)

1.0

1.6

Protection

I

Water-proof

IP20(INDOOR) 

IP24(OUTDOOR)

Climate type

T1

Refrigerant (R22) charge amount (g)

560

1120

Noise dB (A)

31

45

40

48

Net weight (Kg)

10

26

11

37

Dimension (mm) WxHxD

800x183x290

665x295x500

800x183x290

830x310x500

NOTE 

1. The indicated noise value is from laboratory test done before leaving the factory.

 

2. The rated cooling capacity and rated heating capacity value is tested under following conditions.

cooling operation

indoor

27˚C (DB)

19˚C (WB)

outdoor

35˚C (DB)

24˚C (WB)

heating operation

indoor

20˚C (DB)

15˚C (WB)

outdoor

7˚C (DB)

6˚C (DB)

 

3. All of the above information may be changed without notice. These are the latest and    

 

  accurate specifications on the name plate of your air conditioner.

 

4. Working temperature range:

Maximum cooling

Minimum cooling

Maximum cooling

Minimum cooling

Indoor side (DB/WB (˚C)

32/23

21/15

27/--

20/--

Outdoor side DB/WB (˚C)

43/26

21/15

24/18

-5/-6

 

5. If air conditioner working voltage exceeds 230V±10% it may operate abnormally.

 

6. Wiring diagrams of air conditioner (indoor unit/outdoor unit) are attached to the unit.

 

7. If the power cable or connecting cable is damaged, it must be replaced by its service agent  

 

  or similar qualified person in order to avoid a hazard.

Содержание MSS10

Страница 1: ...Reverse Cycle Split System Air Conditioner MSS10 1HP MSS15 1 5HP MSS20 2HP MSS25 2 5HP...

Страница 2: ...e malfunctions of the unit or dew to drip from the unit COMPULSORY WARNING If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in...

Страница 3: ...set sleep operation this operation will cancel when the sleep button is repressed 5 Air flow direction adjustment Change up down air flow direction 1 Press the MANUAL SWING button the deflector will...

Страница 4: ...of indoor unit 4 FAN mode Press MANUAL SWING button or SWING button to change up down air flow direction Press FAN SPEED button to change the fan speed of indoor unit 5 HEAT mode Press MANUAL SWING bu...

Страница 5: ...teries from the remote controller Check before operation CAUTIONS Check that the wiring is not broken and is connected Check that the air filter is installed Check that the outdoor unit air outlet or...

Страница 6: ...door outdoor Function heat pump type heat pump type Power 230V 50Hz 230V 50Hz Rated cooling heating capacity W 2000 2400 3500 4000 Standard input power W 750 cool 730 heat 1300 cool 1380 heat Standard...

Страница 7: ...it must be replaced by its service agent or similar qualified person in order to avoid a hazard 12 13 Performance Parameters cont Model MSS25 2 5HP indoor outdoor Function heat pump type Power 230V 5...

Страница 8: ...E Drain hose 1 6 Remote controller 1 F Opening cap 1 7 Felt 1 G Wall hole cover 1 8 Adiabatic underlay 1 H Indoor wall hole cover 1 9 connecting cable 1 I putty 1 10 Drain joint supplied by customer...

Страница 9: ...may occur because of dust or moisture If necessary consult your supply authority for system impedance information CONNECTING PIPE WORK 1 NOTE The drain must be arranged beneath the copper pipe The dra...

Страница 10: ...n hose and joint CONNECT CONNECTING PIPE Wipe the air sealing oil on the closing valve and the trump extended pipe Screw down the nut of connecting pipe with the wrench the torque is as the indoor uni...

Страница 11: ...f purchase for all parts defective in workmanship or materials The product or defective parts will be replaced free of charge WARRANTY CONDITIONS 1 This warranty is only valid for appliances used acco...

Отзывы: