Problem

Possible Cause

Suggested Remedy

Fan will not start

Fuse circuit breaker 
blown.

Check main branch circuit fuses or circuit breakers.

Loose power line 
connection to the 
Ceiling Fan.

Check line wire connections to Ceiling Fan.

Reversing switch (where 
applicable) neither up or 
down.

Push switch either fully up or down.

Speed controller not in 
correct position.

Check speed controller’s position.

Fan wobbles

Fan blades not horizontal 
to ceiling or blade screws 
are loose.

Measure from ceiling to tip of blades, then rotate fan so 
all 4 blades are checked for equal height from ceiling. 
(Note: adjustments may be made by slight pressure up 
or down on blade holders). Make sure all screws are 
securely fastened.

Fan sounds noisy

Top canopy touching 
ceiling.

Lower canopy from ceiling to ensure minimum 3mm 
clearance.

Light kit glassware loose 
or rattling.

Threaded brass knob securing glass should be finger 
tight.

Incorrect bulb(s) being 
used in light kit.

Check suggested bulb(s) in light kit.

Loose fan blade screws.

Re-tighten all screws on fan blades but never over 
tighten.

Ceiling Fan not secured 
against ceiling.

Re-tighten all screws in the hanging bracket or plate.

Incorrect speed 
controller.

Change the controller to the one supplied.

Mechanical noise

Allow for at least 8 hours settling in period.

These occurrences are not covered by the 
manufacturers’ warranty.

•      All electric motors, including fans make some 

noise and may feel hot if touched-this is not a 
fault.

•      Some fans wobble more than others-even in the 

same model.

•      Fan lights can rattle but are not covered under 

warranty.

•      Fan wall controllers sometimes make a slight 

buzz and can become warm especially on lower 
settings.

Troubleshooting Checklist

M1831.id2

2003.09.05, 14:36

7

Содержание M1831-0

Страница 1: ...Ceiling Fan 120cm 4 Blade Rattan M1831 0 ...

Страница 2: ... controller will void your warranty The use of such controls can cause the ceiling fan motor to produce an unpleasant humming noise FAN INSTALLATION under the warranty this Ceiling Fan must be installed by a licensed electrician Improperly installed Ceiling Fans can be dangerous and expensive to repair Mounting the Ceiling Fan where it is subject to water or moisture can be dangerous Mechanical no...

Страница 3: ...3 Features of your Ceiling Fan All Season Reversible Motor Reversible Timber Rattan Look Blades Light Adaptable 3 Speed Controller Upper Canopy ...

Страница 4: ...al or commercial use Note All ceiling fans must be installed by a Qualified electrical contractor Hangsure Installation Note The bracket must be able to support at least the hanging weight of the fan 15kg To ensure earthing continuity the downrod securing screw must be firmly tightened on the lower canopy 1 Fix the bracket supplied to the ceiling joist by means of two coach screws not supplied or ...

Страница 5: ...ed 7 Connect the speed controller as per wiring diagram Fan Blade Attachment Three Speed Flush Control Note Only use the speed control switch supplied with this fan Electronic speed controllers will not work with this Ceiling Fan 1 The speed control will fit into any existing single gang block or wall plate If you are not flush mounting the control use a standard single gang mounting block 2 Conne...

Страница 6: ...ouple of centimetres is not cause for alarm Such movement is caused by the fact that in order to reduce stress and vibration in the ceiling Ceiling Fans are not rigidly mounted Ceiling Fans are mounted very securely on steel brackets with rubber cushioning or with ball joints to allow free movement Please note that all Ceiling Fans are not the same even in the same model some may move more or less...

Страница 7: ...ing Lower canopy from ceiling to ensure minimum 3mm clearance Light kit glassware loose or rattling Threaded brass knob securing glass should be finger tight Incorrect bulb s being used in light kit Check suggested bulb s in light kit Loose fan blade screws Re tighten all screws on fan blades but never over tighten Ceiling Fan not secured against ceiling Re tighten all screws in the hanging bracke...

Страница 8: ...installation is provided 6 Not designed or warranted for industrial or commercial use DO NOT SEND IN THIS WARRANTY Fill out the following details and file with your purchase invoice RETAIN FILE WITH YOUR RECEIPT Your Purchase Receipt Invoice is proof of date of purchase You must be able to present it at the place of purchase to obtain a replacement or service under warranty Linda Australia Pty Ltd...