Compressor does not start 

  

No current  

Check the voltage 

The thermostat in the off position, or set to minimum set the thermos-
tat position 

Adjust the position of the thermostat 

The thermostat is defective  

Replace the thermostat 

The starting relay is faulty  

Replace 

The starter capacitor is defective  

Replace 

The compressor is defective  

Contact a refrigeration technician 

The compressor works continuously, but the water is not cold 

  

The ice bank is empty 

Check, fill 

There is no ice in the ice bank 

Waiting for ice forming 

There is a gas leak from refrigerant circuit  

Contact a refrigeration technician 

The compressor is defective  

Contact a refrigeration technician 

The water is cold but the appliance is working excessively 

  

There is not enough ventilation  

Move device away from wall 

The ambient temperature exceeds 32°C 

  

The watercooler is noisy 

  

Pipes touch the body and cause vibrations  

Adjust the position of the pipes 

The pressure of water is too low and pump makes noise  

Increase the water pressure 

Cold water comes out gently 

  

The water filter is blocked 

Check, replace 

The solenoid valve is defective  

Check, replace 

The water inlet pressure is too low 

Check, adjust pressure reducer 

The water coil is blocked with ice 

Check the agitator, the thermostat 

Sparkling water is low carbonated 

  

The CO2 pressure is set to less than 5 bar  

Check, adjust 

The bottle of CO2 is empty 

Check, replace 

The temperature of the outlet water is not enough cold 

Set the thermostat to maximum 
(clockwise) 

There is air in the carbonator  

Purge the carbonator 

Only gas is dispensed through the outlet of sparkling water 

  

Level sensors are dirty  

Control, disassemble and clean 

The pump is running continuously there is water in the inlet  

Check Level Controller 

The safety of the pump has been activated (no water)  

Disconnect and reconnect the electri-
cal     network 

The cold water comes out carbonated 

  

The carbonator check valve is dirty  

Disassemble and clean or replace 

FA U LT   C H E C K I N G  

Содержание Horeca G80

Страница 1: ...el d installation Manual Syst mes professionnels HORECA G80 Rev 8 ZI Bois de l Epine 2 avenue Ambroise Croizat 91130 Ris Orangis FRANCE tel 33 0 1 60 79 37 61 fax 33 0 1 60 79 18 26 www mistralcoolers...

Страница 2: ...aine ne sont pas pratiquer par des enfants Si le cordon d alimentation est endommag il doit tre imm diatement remplac par un cordon appropri disponible aupr s du fabricant ou de son prestataire de ser...

Страница 3: ...appliance is intended to be used in household and similar applications such as staff kitchen areas in shops offices and other working environments farm houses and by clients in hotels motels and othe...

Страница 4: ...D bit Eau Gazeuse L min Sparkling water flow seulement sur la version gazeuse only on sparkling version 3 Alimentation V Hz Power supply 230V 50Hz Poids net kg Net weight non gazeux gazeux 29 37 Charg...

Страница 5: ...3 L min or 1 liter in 20 seconds Pression d eau 3 Bars Water pressure 3 Bars Pression CO2 5 Bars CO2 Pressure 5 Bars Entr e d eau Water inlet CO2 CO2 Eau froide Cold water Eau ambiante Ambient water E...

Страница 6: ...ge d brancher le refroidisseur La qualit de la gaz ification d pend de la temp rature de l eau Au moment de l installation il est n cessaire d attendre que le refroidisseur ait refroidi l eau et form...

Страница 7: ...d only be carried out by qualified technicians Before each maintenance or cleaning operation disconnect the cooler The quality of the gasification depends on the temperature of the water At the time o...

Страница 8: ...sur la cuve de r frig ration 9 Connecter les tuyaux d arriv e d eau de CO2 pour les G80 EF ET EG et les sorties votre quipement 10 Ouvrir l arriv e d eau 11 Faire couler de l eau par les moyens de di...

Страница 9: ...page 9 Figure 2 Figure 1 Figure 5 Figure 6 Figure 4 Figure 3...

Страница 10: ...vided fig 9 15 Turn the adjusting screw until the needle on the manometer reaches 5 bar fig 10 16 Check that there are no leaks and that all connections and adjustments are correct 17 Connect the main...

Страница 11: ...page 11 Figure 7 Figure 11 Figure 12 Figure 8 Figure 10 Figure 9...

Страница 12: ...d sinfectant 1 Change the filter after 5000 liters or every 6 months fig 13 2 Before installing the filter and after each filter replacement you need to rinse it fig 14 Connect the filter input and do...

Страница 13: ...page 13 Figure 17 Figure 13 Figure 14 Figure 16 Figure 15...

Страница 14: ...ra R gler la position des tuyaux La pression de l eau est trop faible en entr e et la pompe fait Faire augmenter la pression d eau L eau froide sort doucement Le filtre eau bouch V rifier remplacer L...

Страница 15: ...use vibrations Adjust the position of the pipes The pressure of water is too low and pump makes noise Increase the water pressure Cold water comes out gently The water filter is blocked Check replace...

Страница 16: ...PRESSEUR COMPRESSOR RELAY 17 5727008 RACCORD 6x8 FITTING 6x8 TAIL 6 5216009 CONDENSATEUR DE DEMARRAGE STARTING CAPACITOR 18 5727085 RACCORD SONDE PROBE CONNECTOR 7 5210107 COMPRESSEUR COMPRESSOR 19 57...

Страница 17: ...page 17 SCHEMA ELECTRIQUE ELECTRICAL DRAWING NOTES...

Страница 18: ...page 18 IMPLANTATION...

Страница 19: ...fontaines Connect you to Mistral reseller area and find all technical informations about coolers http www mistralcoolers com fr portail distributeur Retrouvez toute l actualit de Mistral sur All news...

Страница 20: ...e l Epine 2 avenue Ambroise Croizat 91130 Ris Orangis FRANCE tel 33 0 1 60 79 37 61 fax 33 0 1 60 79 18 26 www mistralcoolers com Mistral Constructeur Toute reproduction est interdite Document non con...

Отзывы: