24
EN
Code
Working mode
L00
Load always active (DEFAULT)
L01
Sunlight control with switch off at sunset and switch on at sunrise (NIGHT 1)
L02
Sunlight control with switch switch off point after sunset (time adjustable) and switch on before
sunrise (NIGHT 2)
In main loop "Input Current" interface, by long pressing (>3S)
you can access secondary one-way loop. In secondary loop, by
short pressings
you can circulate interfaces, and by short
pressing
you can change values, while a long-pressing
n main loop "Output Current" interface, by long pressing(>3S)
you can access secondary one-way loop. In secondary loop,
by short pressing
you can circulate interfaces, and by short
pressin
you can change values, while a long-pressing (>S3)
Different load controlling modes define parameters adjustable and interface displayed.
* period adjustable separately.
(>3 S)
enables data saving and exit, and a 20s absence of
operation bring you to main loop interface with data unsaved.
Note: Only parameters of USr type are adjustable.
enables data saving and exit, and a 20s absence of operation
bring you to main loop interface with data unsaved. 3 working
mode for load as below. L00 is the default working mode (load
always active).
5.5 - Charging settings
5.6 - Load working mode
INPUT CURRENT
FLOAT CHARGE VOLTAGE
ABSORPTION
CHARGE VOLTAGE
EQUALIZED
CHARGE VOLTAGE
OUTPUT CURRENT
VOLTAGE OF LVD
LOAD-ON DURATION
BEFORE DAWN
VOLTAGE OF LVR
LOAD-ON DURATION
AT NIGHT
LOAD WORKING MODE
LOAD SWITCH-ON POINT
(SUNLIGHT LEVEL)
L00
mode DEFAULT
mode NIGHT 1
mode NIGHT 2
L01
on
on
on
off
off
L02
night*
dawn*