18
Xantrex XPower 3000 Owner's Guide
Operating
Condition
Battery
Voltage
Comment
Low voltage
shutdown
less than
10.5 volts
The XPower inverter shuts down to
protect the battery from being over-
discharged.
High voltage
shutdown
15 volts or
more
The XPower inverter shuts down to
protect itself from excessive input
voltage.
NOTE
: Although the XPower
inverter incorporates over-voltage
protection, it can still be damaged if
input voltage exceeds 16 volts.
Inverter Loads
The XPower inverter will operate most AC loads within its power
rating. However, some appliances and equipment may be difficult
to operate, and other appliances may actually be damaged if you
try to operate them with the inverter. Please read
and
carefully.
The XPower inverter will operate many AC loads within its power
rating. However, some appliances and equipment may be difficult
to operate. Please read
carefully.
High Surge Loads
Some induction motors used in freezers, pumps, and other motor-
operated equipment require high surge currents to start. The
inverter may not be able to start some of these motors even
though their rated current draw is within the inverter’s limits. The
inverter will normally start single-phase induction motors rated at
3/4 horsepower or less.
Содержание xantrex XPower 3000
Страница 1: ...XPower Inverter 3000 Owner s Guide XPower 3000 813 3000 UL...
Страница 10: ...This page is intentionally left blank...
Страница 25: ......
Страница 26: ...975 0555 01 01 Rev C http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...
Страница 27: ...Onduleur XPower 3000 Guide du propri taire XPower 3000 813 3000 UL...
Страница 36: ...Cette page est vierge...
Страница 55: ......
Страница 56: ...975 0555 02 01 R v C http www xantrex com 1 800 670 0707 1 408 987 6030 Imprim en...