background image

Important Safety Notice

3

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

CAUTION

7RUHGXFHULVNRI¿UHDQGWRSURSHUO\H[KDXVWDLURXWVLGH'RQRWYHQWH[KDXVWDLULQWRVSDFHVZLWKLQZDOOVFHLOLQJV

attics, crawl spaces or garages.

Not for use over an outdoor grill.

This hood is not intended to be used as a shelf. 

OPERATION

$OZD\VOHDYHVDIHW\JULOOHVDQG¿OWHUVLQSODFH:LWKRXWWKHVHFRPSRQHQWVRSHUDWLQJEORZHUVFRXOGFDWFKRQWRKDLU¿QJHUV

and loose clothing.

The manufacturer declines all responsibility in the event of failure to observe the instructions given here for installation, 
maintenance and suitable use of the product. The manufacturer further declines all responsibility for injury due to 
negligence and the warranty of the unit automatically expires due to improper maintenance.

ELECTRICAL REQUIREMENTS

Important:

Observe all governing codes and ordinances.

It is the customer’s responsibility:

 7RFRQWDFWDTXDOL¿HGHOHFWULFDOLQVWDOOHU

-  To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 

latest edition* or CSA standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and 
all local codes and ordinances.

,IFRGHVSHUPLWDQGDVHSDUDWHJURXQGZLUHLVXVHGLWLVUHFRPPHQGHGWKDWDTXDOL¿HGHOHFWULFLDQGHWHUPLQHWKDWWKH

ground path is adequate.

Do not ground to a gas pipe.

&KHFNZLWKDTXDOL¿HGHOHFWULFLDQLI\RXDUHQRWVXUHWKHUDQJHKRRGLVSURSHUO\JURXQGHG

Do not have a fuse in the neutral or ground circuit.

*National Fire Protection Association Batterymarch Park, Quincy, Massachusetts 02269 
** CSA International 8501 East Pleasant Valley Road, Cleveland, Ohio 44131-5575

This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit 
protected by a 15 or 20 ampere circuit breaker or time delay fuse.  Wiring must be 2 wire with ground.  Please also refer to 
Electrical Diagram on product.

$FDEOHORFNLQJFRQQHFWRUQRWVXSSOLHGPLJKWDOVREHUHTXLUHGE\ORFDOFRGHV&KHFNZLWKORFDOUHTXLUHPHQWVSXUFKDVH

and install appropriate connector if necessary.

MH00830AS, MH00836AS -  400 Watts, 3.4 Amps

Содержание MH00830AS

Страница 1: ...Installation Use and Care Guide READ AND SAVE THESE INSTRUCTIONS 2014 NOV MH00830AS MH00836AS MODEL ...

Страница 2: ......

Страница 3: ...g Height Clearance 6 Ducting Options 7 RRG 6SHFL FDWLRQV 8 Mounting the Hood 9 Ductless Recirculating 10 FEATURES CONTROLS Electronic Controls 11 MAINTENANCE Hood and Filter Cleaning 12 Light Bulbs 13 TROUBLESHOOTING 14 WIRING DIAGRAMS 15 LIST OF PARTS AND ACCESSORIES 16 Table of Contents ...

Страница 4: ...ensils appropriate for the type of and amount of food being prepared WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING D 6027 5 0 6 ZLWK D FORVH WWLQJ OLG FRRNLH VKHHW RU PHWDO WUD WKHQ WXUQ RII WKH EXUQHU 5 8 72 35 9 17 8516 I WKH ÀDPHV GR QRW JR RXW LPPHGLDWHO 9 8 7 1 7 5 3 570 17 b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WA...

Страница 5: ...electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances I FRGHV SHUPLW DQG D VHSDUDWH JURXQG ZLUH LV XVHG LW LV UHFRPPHQGHG WKDW D TXDOL HG HOHFWULFLDQ GHWHUPLQH WKDW WKH ground path is adequate Do not ground to a ga...

Страница 6: ...es Extension duct cover accessory RHEX008S Recirculating kit accessory RHRK008S HARDWARE PACKAGE CONTENTS 1 Suction Cup PARTS SUPPLIED MODELS MH00830AS MH00836AS 1 Hood with internal blower 1 Duct cover wall bracket 1 Duct cover assembly top and bottom 1 Hardware package 1 6 round backdraft damper pre installed 2 50W GU 10 halogen light bulbs 2 Aluminum mesh filters ...

Страница 7: ...lent number length x used 6 8 Round wall cap with damper 30 Ft x Ft Round wall cap with damper 30 Ft x Ft 7 or 8 Round 900 elbow 15 Ft x Ft 7 or 8 7 or 8 Round 450 elbow 9 Ft x Ft Ft Ft Ft 6 8 Round roof cap 30 Ft x Ft 7 or 8 Round roof cap 30 Ft x Ft Subtotal column 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length of a 3 1 4 x 10 rectangul...

Страница 8: ...SHUIRUPDQFH DQG HI FLHQF If available also refer to range manufacturer s height clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Duct cover extension kit available for ceiling heights up to 12 feet Turn to page 16 for part number and ordering information D DAMAGE SHIPMENT INSTALLATION 3OHDVH IXOO LQVSHFW XQLW IRU GDPDJH EHIRU...

Страница 9: ...ide unless using the recirculating option Use single wall rigid metal ductwork only DVWHQ DOO FRQQHFWLRQV ZLWK VKHHW PHWDO VFUHZV DQG WDSH DOO MRLQWV Z FHUWL HG 6LOYHU 7DSH RU XFW 7DSH Some Ducting Options Installation Ducting Options side wall cap w gravity damper Soffit or crawl space Roof Pitch w Flashing Cap ductless recirculating side wall cap w gravity damper ...

Страница 10: ... RRG 6SHFL FDWLRQ 6 CL 29 15 16 35 7 16 14 1 8 2 13 16 20 1 16 STANDARD min ducted 26 min recirc 31 max 53 RHEX008S EXTENSION min ducted 42 min recirc 46 max 80 11 7 1 16 9 7 16 10 9 16 2 3 16 3 9 16 5 TOP SIDE FRONT ...

Страница 11: ...h duct cover mounting bracket to wall just EHORZ WKH FHLOLQJ RU VRI W XVLQJ 0 VFUHZV 10 Install duct work and seal with aluminum duct tape Re install MXQFWLRQ ER ZLWK FDEOH ORFN DQG LQVWDOO WKH HOHFWULFDO 11 Power up hood to verify all functions and check for leaks around duct tape 3ODFH WHOHVFRSLF GXFW FRYHUV RQWR KRRG DQG H WHQG LQQHU WRS GXFW FRYHU XSZDUGV DQG VHFXUH WR GXFW FRYHU EUDFNHW XVLQJ...

Страница 12: ...HUV KHOS WR SXULI IXPHV H KDXVWHG IURP cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED LW LQFOXGHV FKDUFRDO OWHUV FKDUFRDO OWHU EUDFNHWV DQG DLU GLYHUWHU SODWH Hood Models Part No Filters Brackets in pkg MH008 RHRK008S 2 1 Purchase recirculating kit per the part number above 6HFXUH DLU GLYHUWHU SODWH WR ZDOO EHORZ GXFW FRYHU EUDFNHW 5XQ 6 ducting from top of hood and se...

Страница 13: ... Blower Speed Selection 2 Delay Off Timer 4 Blower On Off Press to turn blower on and off If lights are on they will also switch off when this button is pressed Press to cycle through light levels Bright Dim and Off 4 Delay Off Timer Press to enable delay off timer blower will shut down after 5 minutes Features Controls Electronic Controls ...

Страница 14: ...h clean cotton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Aluminum Mesh Filters 7KH DOXPLQXP PHVK OWHUV LQVWDOOHG E WKH IDFWRU DUH LQWHQGHG WR OWHU RXW UHVLGXH DQG JUHDVH IURP cooking They need not be replaced on a regular basis but are required to be kept clean Remove and clean by hand or in dishwasher on low heat Spray degreasing deterge...

Страница 15: ...HPRYH E WXUQLQJ EXOE FRXQWHU FORFNZLVH 1RWH XOE GRHV QRW XQVFUHZ LW WXUQV GHJUHHV stops and falls out I EXOEV DUH GLI FXOW WR WXUQ GXH WR SURORQJHG XVH UPO DWWDFK WKH LQFOXGHG JODVV VXFWLRQ FXS RU XVH D UXEEHU latex glove grip and turn the bulb counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type GU 10 50W halogen For part numbers please turn to page 16 of t...

Страница 16: ...ion properly after the thermally protected system cool down 5 Damaged capacitor 5 Change the capacitor 6 The switch board or control board is defective 6 Change defective part The unit is vibrating 1 The blower is not secured in place 1 Tighten the blower in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood The blower is worki...

Страница 17: ...15 Wiring Diagrams MH00830AS MH00836AS ...

Страница 18: ... DESCRIPTION PART Replacement Parts LJKW XOE 8 HDFK Optional Accessories Recirculating Kit RHRK008S 5HSODFHPHQW KDUFRDO LOWHUV HDFK 5 Extension Duct Cover RHEX008S Order replacement parts from us by calling 1 888 750 1698 ...

Страница 19: ... you are also responsible for all labor costs associated with this warranty Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY WE SHALL NOT BE LIABLE FOR INCIDENTAL CONSE QUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE PRODUCTS THE EXPRESS WARRANTIES IN THE PRECEDING SE...