LT-1201 Rev 3.1 http://www.mircom.com
Page 3 of 4
Figure 3 Location of the microphone opening on the new microphone
2. Open the door.
3. From the front of the door, insert the multimeter probe through the door’s microphone
opening.
4. Carefully insert the tip of the multimeter probe into the microphone opening on the
microphone.
Caution:
The microphone on the other side of the opening is very delicate.
Permanent damage to the microphone can result if you force the tip of the
multimeter probe too far into the microphone opening.
5. Align the microphone so that the terminal for the wiring harness is on the bottom (see
Figure 4).
Figure 4 Proper alignment of the of the microphone board
6. Using the multimeter probe as a guide, move the microphone towards the door until the
microphone attaches to the door.
Figure 5 Aligning the microphone with the microphone hole
Microphone
opening
Adhesive
Terminal for the
wiring harness
on bottom