NV9604 Control Panel • User’s Guide
27
5. Operation
Operating Concepts
A forced release is when the lock or protect is removed by someone other than the owner. A forced
release can be performed:
• At any panel configured with release mode set to “forced release.”
• At any other panel with “force release” enabled.
Takes
The NV9604 can operate by itself as a stand-alone panel or as an extension to an NV9602. As an
extension to an NV9602, it operates according to the mode in which the NV9602 is configured.
Pressing a source button completes a take, in all cases. Following are brief instructions on how to
perform a take under 4 cases.
Case 1
—
Stand-Alone Panel, Single-Destination Mode
The single destination is the one defined as the default destination. Takes all-level.
Press a source button to perform (and complete) a take.
Case 2
—
Stand-Alone Panel, X-Y Mode
Takes all-level. Follow these steps:
1 Press a destination button.
2 Press a source button to perform (and complete) a take.
Case 3
—
NV9602 Extension, Single-Destination Mode
Takes in single-destination mode are all-level. Follow these steps:
1 Verify that the default destination appears in the ‘Destination’ field of the NV9602 display.
2 Optionally press ‘Source Shift’ (on the NV9602) to toggle between the source sets.
3 Press a source button on the NV9602 or NV9604 to complete the take. The ‘Status’ field of the
NV9602 display shows the source you chose.
Case 4
—
NV9602 Extension, Single-Destination Mode, Breakaway
Takes in single-destination mode with breakaway are meant to be on selected levels. Follow these
steps:
1 Verify that the default destination appears in the ‘Destination’ field of the NV9602 display.
2 Press one or more level buttons on the NV9602 to select the levels you want to route. The levels
that are available are those of the default destination. If your panel has a ‘None/All’ button, you
can press that button to toggle between all levels being selected and no levels being selected.
3 Optionally press ‘Source Shift’ (on the NV9602) to toggle between the source sets.
4 Press a source button on the NV9602 or NV9604 to complete the take. The ‘Status’ field of the
NV9602 display shows the source you chose.
S
A take is all-level when all the level buttons are selected (high-tally) or when none of the level
buttons are selected.
S
If your NV9602 has a ‘Hold’ button, you can use it to preserve the chosen breakaway levels
after the take. Hold “mode” is active when the hold button is high-tally. When hold mode is
inactive, the destination reverts to all levels after the take.