GUIDE TO INSTALLATION AND OPERATION
FIO-1901-RR |
13
3.3.4 The
Output & Optical
panel
Manually configure the input-to-output connections. Each of
the two electrical outputs can be connected to either of the
two optical inputs. The default is A-to-A and B-to-B.
•
When
Fail Over
is ON, the configuration is fixed and
the settings made here are overridden. See section
3.3.5 below.
3.3.5 The
Fail Over
panel
When Failover mode is activated, the FIO-1901-RR is
configured with
Optical In A
as the source for both outputs,
and
Optical In B
as the backup. If
Optical In A
fails, the
outputs will be switched over to
Optical In B
(if it is valid),
after a defined delay. The delay can be set between 0 and
15 seconds, in order to accommodate deliberate or
anticipated breaks in the input data stream.
Mode:
Use the radio buttons to set the operating mode
to OFF or ON
Fail Delay: Use the slider to set the delay between the
detection of a failure on
Optical In A
and the
switchover to
Optical In B
(range is 0 to 15
seconds)
Note that turning this mode ON overrides the output
configuration set in the Output & Optical panel. See
section 3.3.4 above.
Figure 3.6
Output & Optical panel
Figure 3.7
Fail Over panel