Miranda Densite series DDA-1113 Скачать руководство пользователя страница 2

GUIDE TO INSTALLATION AND OPERATION 
 

DDA-1113 
 

Electromagnetic Compatibility 

 

This equipment has been tested for verification of compliance with FCC Part 15, Subpart B requirements for 

Class A digital devices. 

NOTE:

 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 

radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful 

interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful 

interference in which case the user will be required to correct the interference at his own expense. 

 

 

This equipment has been tested and found to comply with the requirements of the EMC directive 

2004/108/CE: 

 

EN 55022 Class A radiated and conducted emissions 

 

EN 55024 Immunity of Information Technology Equipment 

 

EN 61000-3-2 Harmonic current injection 

 

EN 61000-3-3 Limitation of voltage changes, voltage fluctuations and flicker  

 

EN 61000-4-2 Electrostatic discharge immunity 

 

EN 61000-4-3 Radiated electromagnetic field immunity 

– radio frequencies 

 

EN 61000-4-4 Electrical fast transient immunity 

 

EN 61000-4-5 Surge immunity 

 

EN 61000-4-11 Voltage dips, short interruptions and voltage variations immunity 

 

 
 

 

 
 
 
 
 

How to contact us: 

 

For technical assistance, please contact the Miranda Technical support centre nearest you: 

 
Americas 

Telephone:  

  +1-800-224-7882 

e-mail: 

  [email protected] 

 
Asia 

Telephone:  

  +852-2539-6987 

e-mail: 

  [email protected]  
 

 
Europe, Middle East, Africa, UK 

Telephone:  

  +44 (0) 1491 820222 

e-mail: 

  [email protected] 

 

 

China 

Telephone:  

  +86-10-5873-1814 

e-mail: 

  [email protected]

 

France (only) 

Telephone:  

 

+33 (0) 1 55 86 87 88 

e-mail: 

 

[email protected] 

 

Visit our web site at 

www.miranda.com

 

Содержание Densite series DDA-1113

Страница 1: ......

Страница 2: ...quipment has been tested and found to comply with the requirements of the EMC directive 2004 108 CE EN 55022 Class A radiated and conducted emissions EN 55024 Immunity of Information Technology Equipm...

Страница 3: ...6 2 Installation 7 2 1 Unpacking 7 2 2 Installation in the Densit frame 7 2 3 Rear Connector Panel 7 3 Operation 8 3 1 Card Edge Controls and Indicators Status Led 8 3 2 Local control using the Densi...

Страница 4: ...GUIDE TO INSTALLATION AND OPERATION DDA 1113...

Страница 5: ...he content of the audio signal A multi colored LED visible with the door closed reports the card status The DDA 1113 requires a single or a double rear connector panel 1 2 Features Digital audio distr...

Страница 6: ...terface The front card edge of the DDA 1113 incorporates two elements Status LED see section 3 1 Select Button see section 3 2 Figure 1 2 Card edge controls and indicators SDA 1101 SD DIGITAL VIDEO DI...

Страница 7: ...st be mounted in a DENSIT 2 or DENSIT 3 frame It is not necessary to switch off the frame s power when installing or removing the card See the DENSIT Frame manual for detailed instructions for install...

Страница 8: ...dition cannot cause the LED to assume that status If more than one LED status is possible for a particular error condition the status is configurable See Section 3 2 2 for details The factory default...

Страница 9: ...pushbuttons located beneath the display The functionality of the pushbuttons is as follows Used for menu navigation and value modification SELECT Gives access to the next menu level When a parameter v...

Страница 10: ...to a correct input status LENGTH This command allows a manual adjustment of the correction applied to the input signal The input status is displayed at the same time to ease the setting o Set the inpu...

Страница 11: ...t of factory selected values that can be used to return your DDA 1113 to a standard operating condition The default values are shown as underlined in the DDA 1113 Menu on page 10 3 3 1 Status Tab This...

Страница 12: ...f selected individual alarms to the status LED located on the front card edge The Card LED status is shown at the bottom of the alarm tree in the Status Name column Overall Alarm This column allows co...

Страница 13: ...of alarm events for each individual alarm At the bottom of the window are several other controls Overall alarm and GSM contribution follow card LED Click in the checkbox to force the Overall alarm and...

Страница 14: ...A 1113 The boxes titled Label Short Label Source ID and Comments are editable the user can enter their own information The Advanced button displays the name of the server within the iControl system th...

Страница 15: ...tputs Signal AES3 id SMPTE 276M Level 1 Vpp Impedance 75 unbalanced Rise fall time 36 32 ns Overshoot 0 Return loss 15 dB 6 144MHz Jitter reduction 6 dB 20 kHz Specific jitter 0 005 UI pp 700 Hz to 10...

Отзывы: