GUIDE TO INSTALLATION AND OPERATION
HDA-1861 |
7
2 Installation
2.1 Installation of Rear Connector Panels
Miranda Densité-series cards are each associated with a rear connector panel, which must be installed in the Densité
frame before the card can be inserted.
The HDA-1861 card is sized to fit into Miranda’s Densité-2 frame. Two different rear connector panels are available to
fit the Densité 2 frame:
•
HDA-185N/186N-SRP – 1 input and 4 outputs
•
HDA-185N/186N-DRP – 1 input and 9 outputs
With the use of an available adapter, the HDA-1861 can also be installed in a Densité-3 frame (see section 2.3
below). A rear connector panel for this frame is available for the HDA-1861:
•
HDA-185N/186N-3SRP – 1 input and 7 outputs
The two Densité-2 rear panels can also be used in a Densité-3 frame, with the addition of available adapters:
•
HDA-185N/186N-SRP
+
DENSITE
SRP-3RU – 1 input and 4 outputs
•
HDA-185N/186N-DRP
+
DENSITE
DRP-3RU – 1 input and 9 outputs
All cards and rear panels can be installed with the frame power on. The card has connectors which plug into a mid-
frame mother board for distribution of power and for connection to the controller card, and a second connector which
plugs directly into the rear connector panel for input and output.
The rear connector panel must be installed with the card out of the frame.
•
To remove an existing card from the slot, tilt up the swivel handle on the front of the card to lever the connectors
apart, then use the handle to pull the card straight out of the slot.
Densité-2 frame – rear panel installation
Densité-3 frame – rear panel installation
To install the connector panel:
(NOTE - if you are installing a Densité-2 rear panel plus adapter in a Densité-3 frame, please go to section 2.3)
1. If a card is installed in the slot whose rear panel is being changed, remove it as described above.