OPERATION (continued) 

STATUS menu 

 

Displays status of the different board alarms. The higher-level 
alarm is displayed, even if not configured to activate the 
STATUS LED. 

ALL OK 

indicates an absence of alarm. 

REAR PANEL ERROR

 

Indicates an absence of the rear 

panel or an incompatibility between the module and the rear 
panel. The STATUS led turns on flashing red  

NO LOCK  

Indicates that the input stage is not locked on the 

incoming AES

.

 

BIPHASE CODING  

Indicates a biphase coding error . 

PARITY  

Indicates a parity error. 

CRCC  

Indicates a CRCC error. 

SLIPPED

   

Indicates a sample slipping.

 

CONFIDENCE  

Indicates an input signal up to be low.

 

INVALID  

Indicates an invalid sample. 

NON AUDIO  

Indicates the audio content is not linear PCM 

samples.

 

NO SIGNAL   

Indicates an internal signal level lower than the 

selected threshold during a user defined period.

 

NO SIGNAL DELAY menu 

Signal absence is declared when the level signal is lower than 
the signal threshold during the selected period, it can be 
adjusted from 0 to 255 s. The default value is set to 15 s. 

SIGNAL THRESHOLD menu 

The absence signal threshold can be adjusted from –72 to –48 
dBFS by 6 dB steps. The default value is –60 dBFS. 

CABLE CORRECTION menu  

AUTO  

  A 

START

 will initiate an automatic sequence, indicated 

by 

PROCESS

. When the input status becomes correct it will 

stop and 

SUCCESS

 will be displayed. 

FAIL

 will be displayed to 

indicate that no correction has been found that will yield a 
correct input status. 

MANUAL  

This command allows a manual adjustment of the 

correction applied to the input signal. The input status is 
displayed at the same time to ease the setting. 

CONFIGURE ALARM 

It is possible to associate the 

STATUS

 Led colour and/or a 

GPI relay activation to each detected error. 

Alarm relay activation depends of the ENABLE selection of 
the controller board menu GPI REPORT. 

ALARM LEVEL  

Associates to each error the 

STATUS

 led 

colour: GREEN, YELLOW, RED and FLASH RED. This 
selection has no influence on the {STATUS} menu display. 

ALARM REPORT 

 The default value NONE is assigned to 

errors. Alarm relay activation will be associated to an error 
when GPI is set. 

FIRMWARE VERSION menu 

  UC = Vxxx  

Microcontroller firmware version 

  CPLD = Vx

 

 

Programmable logic element firmware 
version. 

FACTORY DEFAULT menu  

RESTORE

  

Select 

RESTORE

 to reset all of the menu-adjustable 

parameters to a factory-preset state (indicated in the menu chart 
by an underline in the list of available choices) 

 

 

 

 

 

iControl INTERFACE 

The operation of the DDA-1112 may be controlled using Miranda’s iControl system.  

This section describes the control panels associated with the DDA-1112 and their uses.  

Please consult the iControl User’s Guide for information about setting up and operating 
iControl. 

In iControl Navigator or iControl Websites, double-click on the DDA-1112 icon to open 
the control panel. 

Status Icons 

At the top, to the left of the Miranda logo, are two status icons that report various 
aspects of the card’s operation.  

The leftmost (CTRL) icon shows whether card configuration is manual [LOC] or via 
iControl [REM]. The second icon reports the input status

Move the cursor over an icon to see its current status in the message area below the 
icons. If there is an error status, the message will appear automatically. If there are 
multiple error messages, the display will cycle through them. 

The higher level alarm is displayed below inside the Status tab. 