Log Set

The Ceramic logs are durable and long lasting when installed
properly.  However, they are delicate and may be damaged
easily if not handled with care.  Unpack and inspect log set.
There should be a total of 4 logs as shown in Fig. # 16.  All gas
and venting connections should be made before installing log
set.

Log Assembly:    

(Fig. # 15)

1) Place the rear log in position at the back of the firebox,

centered between the brackets, with flat side facing rear
and the bark side facing forward.

2) Place the front log over the two pins just in front of the rear

burner onto  the tabs located at the front of burner
assembly.  The log is notched to fit over the pilot.

3) The top left "Y" log bridges across front and rear log.  The

log should be properly seated over pin in the front log and
nested in the left relief of the rear log.

4) The top right log also bridges across the front and rear log.

The log should be properly seated over the pin in the front
log and nested in the right relief of the rear log.

Note:  Improper placement of logs may cause sooting on
internal parts and glass.

Fig # 15

Left "Y" Log

Front
Log

Back Log

Right Log

Fig. #16

Back Log

Front Log

Top Left "Y" Log

Top Right Log

f i r e - p a r t s . c o m

Содержание SERIES A

Страница 1: ...t touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supp...

Страница 2: ...evelling Legs 10 Log Set 11 Surround Assembly 12 First Fire 13 Operation 13 Primary Air Adjustment 13 Optional Blower 15 Replacement Parts 16 Glass Frame Removal 18 Optional Radiant Overlay 18 Appendi...

Страница 3: ...nal service person More frequent cleaning may be required due to excessive lintfromcarpeting beddingmaterial etc Itisimperative that control compartments burners and circulating air passageways of the...

Страница 4: ...s of the standards for chimneys fireplaces vents and solid fuel burning appliances NFPA 211 Latest Edition or applicable National Provincial State or local codes The factory built zero clearance firep...

Страница 5: ...enings and combustion air supplies are required Fig 4 Fig 5 MINIMUM CLEARANCES TO COMBUSTIBLES Adjacent sidewall 6 0 in 152 mm Ceiling to appliance 50 in 1270 mm Mantel to appliance 18 in 457 mm Maxim...

Страница 6: ...ews provided 3 Insert both flex liners from top of the chimney down through the damper opening 4 The vent terminal is sized to fit most typical chimneys Before attaching vent terminal to top of chimne...

Страница 7: ...n into position and attach in place with screw previously removed Leave the Insert extend ing a couple of inches out of the fireplace temporarily to allow for proper surround placement Rocker Switch N...

Страница 8: ...ngage from the top and place in a safe place to avoid damage 3 Remove the wrapped logs and brick panels and set aside taking care not to damage them 4 Remove burner assembly from the carton and inspec...

Страница 9: ...ided Fig 13 9 Connect the wire harness from the rocker switch to the control valve ter minal marked TH and TH TP Fig 12 Feed the wire through the smaller plastic bushing located next to the gas inlet...

Страница 10: ...ht so that it tucks in behind the right side panel leaving room for the left panel to pass by it 3 Similarly to installing the right panel push the left panel all the way to the rear to clear the wind...

Страница 11: ...the front log over the two pins just in front of the rear burner onto the tabs located at the front of burner assembly The log is notched to fit over the pilot 3 The top left Y log bridges across fron...

Страница 12: ...Slide the assembled brass trim over the surround from the top Fig 17 5 Tighten the retaining screws at the bottom of each brass trim side Fig 21 Fig 18 Fig 19 6 Connect the wire from the gas control...

Страница 13: ...the front burner Pulling the left rod forward closes the rear shutter and increasestherearflameheight Pushingtherightrodupwards closes the front shutter and increases flame height of the front burner...

Страница 14: ...est setting if applica ble 3 Turn off all electric power to the appliance 4 Open the bottom grill to access the controls 5 Partially depress and turn gas control knob clockwise past Pilot to Off posit...

Страница 15: ...emporar ilyintherightfrontcorneroftheappliance The junction box attaches to the underside of the burner assembly once in place Fig 27 3 Feed the power cord out through the plastic grommet on the side...

Страница 16: ...ht MIND 509771 16 Surround Trim Left MINC 1664 17 Surround Trim Top MINC 16641 18 Surround Trim Right MINC 16642 19 Surround Side Left MINC 1658_ _ 20 Surround Top MINC 1659_ _ 21 Surround Side Right...

Страница 17: ...17 Fig 28 fire parts com...

Страница 18: ...f removal During installation ensure that the tabs on the top of the unit engage the corre sponding slots in the glass frame Fig 30 Optional Radiant Overlay The optional Radiant Overlay may be install...

Страница 19: ...t only Please refer to the Installation Instructions provided with the appliance for proper installation This box contains Direct Vent Insert Vent Terminal Kit Vent Terminal MIND VTTERM 1 Vent Termina...

Страница 20: ...l Flashing 4 8 x 1 Sheet Metal Screws Installation 1 Attach the vent terminal to the flashing using the 4 screws provided 2 Attach the flashing to the chimney by first notching and then bending the ex...

Страница 21: ...rt Installation Please see instruction manual This kit contains 1 Blower assembly including blower control box and power cord 2 Wing nuts 2 8 x 1 2 Sheet metal screws black in color Optional Blower Ki...

Страница 22: ...and inspect all parts A flathead or a 2 Robertson screwdriver is required to install the louvers 1 Fasten top louver to the top casing with the screws provided see Fig 1 2 Fasten bottom louver to the...

Страница 23: ...xiste aucun code local se conformer a la norme CAN CGA B149 en vigueur Left and Right side are determined when facing the front of the appliance Les cotes droit et gauche se determinent en se mettant...

Страница 24: ...Pacific Energy Fireplace Products Ltd Box 1060 Duncan B C V9L 3Y2 Phone 250 748 1184 Web site http www pacificenergy bc ca Printed in Canada fire parts com...

Отзывы: