48
6.
Feed the signal wire through this slot, from the
back of the unit to the front.
7.
Facing the front of the unit, match the wire col
-
ors with the labels on the terminal block, connect
the u-lug and and firmly screw each wire to its
corresponding terminal.
8.
After checking to make sure every connection
is secure, use the cable clamp to fasten the
signal cable to the unit. Screw the cable clamp
down tightly.
9.
Replace the wire cover on the front of the unit,
and the plastic panel on the back.
Step 7: Wrap piping and cables
Before passing the piping, drain hose, and the
signal cable through the wall hole, you must bun-
dle them together to save space, protect them,
and insulate them.
1.
Bundle the drain hose, refrigerant pipes, and
signal cable according to Fig. 4.20
DO NOT MIX UP LIVE AND NULL WIRES
This is dangerous, and can cause the air
conditioning unit to malfunction.
THE WIRING CONNECTION PROCESS MAY
DIFFER SLIGHTLY BETWEEN UNITS
DO NOT INTERTWINE SIGNAL CABLE
WITH OTHER WIRES
While bundling these items together, do not
intertwine or cross the signal cable with any
other wiring.
2.
Using adhesive vinyl tape, attach the drain
hose to the underside of the refrigerant pipes.
3.
Using insulation tape, wrap the signal wire,
refrigerant pipes, and drain hose tightly together.
Double-check that all items are bundled in accor-
dance with Fig. 4.20
Step 8: Mount indoor unit
If you installed new connective piping to the
outdoor unit, do the following:
1.
If you have already passed the refrigerant
piping through the hole in the wall, proceed to
Step 4.
2.
Otherwise, double-check that the ends of the
refrigerant pipes are sealed to prevent dirt or
foreign materials from entering the pipes.
3.
Slowly pass the wrapped bundle of refrigerant
pipes, drain hose, and signal wire through the
hole in the wall.
4.
Hook the top of the indoor unit on the upper
hook of the mounting plate.
5.
Check that unit is hooked firmly on mount
-
ing by applying slight pressure to the left and
right-hand sides of the unit. The unit should not
jiggle or shift.
6.
Using even pressure, push down on the
bottom half of the unit. Keep pushing down
until the unit snaps onto the hooks along the
bottom of the mounting plate.
7.
Again, check that the unit is firmly mounted
by applying slight pressure to the left and the
right-hand sides of the unit.
DRAIN HOSE MUST BE ON BOTTOM
Make sure that the drain hose is at the bot-
tom of the bundle. Putting the drain hose at
the top of the bundle can cause the drain
pan to overflow, which can lead to fire or
water damage.
CAUTION
NOTE ABOUT WIRING
Fig. 4.20
Indoor Unit
Space behind unit
Re
frigerant piping
Drain hose
Signal wire
Insulation tape
Содержание IVIH121A
Страница 6: ...6 Unit Parts Unit Specifications and Features...
Страница 16: ...16 Troubleshooting When troubles occur please check the following points before contacting a repair company...
Страница 31: ...31 INSTALLATION...
Страница 35: ...35 Owner s Installation manual...
Страница 36: ...36 Installation Summary Indoor Unit...
Страница 37: ...37...
Страница 59: ...6700 Gateway Park Dr Unit 6 San Diego CA 92154 Ph 619 426 0033 mirageappliances us...