FAULT DIAGNOSIS
In the event of a malfunction of the shower, the troubleshooting information below
!!!
=`
section in the users guide.
WARNING
There are no user serviceable components beneath the cover of the shower.
%&
Symptom
Start/Stop
Light is
ON or OFF
Power
Control
Position
Possible Cause
Possible Remedy
Shower fails
to operate.
OFF
=
Isolator switch in the off
position.
Fuse blown or MCB/RCD
tripped, indicating possible
electrical fault.
Service tunnel or cover
Start/Stop button to not
operate.
Switch on electrical supply
via the pullcord or wall
mounted switch.
Renew the fuse or reset
the MCB/RCD. If fault
persists, contact your
installer.
Check case inserts are cut
+[
s e r v i c e s ( e l e c t r i c a l o r
!#
with location of service
tunnel or cover.
Shower
cycles from
hot to cold
.
ON
ECO/
HIGH
Showerhead blocked.
Hose kinked or blocked.
Water pressure below
minimum required for
shower operation.
Temperature control or
power control setting too
high.
Remove and descale
showerhead.
Check hose and replace if
necessary.
Make sure incoming mains
water stopcock and/or
shower isolating valve is
fully turned on.
Turn the power control
to Eco or turn the
temperature control until
a cooler temperature is
achieved.
Unable to
select a
cool enough
shower.
ON
=
Due to the rise in mains
water supply temperature,
the power control setting
may be too high.
Turn the power control
to Eco or turn the
temperature control until
a cooler temperature is
achieved.