INTRODUCTION

Thank you for purchasing a quality Mira product. To enjoy the full potential of your 

new product, please take time to read this guide thoroughly, having done so, keep 

it safe for future reference.

DESCRIPTION

Mira 1.5 bar Twin Ended Pump

Mira 2.0 bar Twin Ended Pump

An electric motor driven twin ended peripheral pump complete with an automatic 

control system, consisting of flow switches and electronic controls.

CAUTION!

1.

 

Read all of these instructions and retain this guide for later use.

2.

 

Follow all warnings, cautions and instructions contained on the appliance.

3.

 

DO NOT

 fit the appliance where it may be exposed to freezing conditions.

4. 

The appliance is not suitable for areas with high humidity (i.e. steam rooms).

5.

 

The electrical installation must comply to "BS 7671 (commonly referred to 

as the IEE Wiring Regulations) and all relevant building regulations, or any 

particular  regulations  or  practices  specified  by  the  local  electricity  supply 

company.

6.

 

The plumbing installation must comply with all national or local water 

regulations and all relevant building regulations, or any particular regulation 

or practice specified by the local water supply company.

7. 

To avoid damage to the appliance when soldered fittings are used, pre-solder 

the pipework and fittings before connecting them to the flexible hoses.

8. 

To make sure the appliance and supplied fittings are not put under strain 

during installation, always provide mechanical support when making plumbing 

connections. Upon completion of the installation, make sure the connections 

are not under any stress due to misaligned pipework or electrical cables.

9. 

DO NOT

 commission this appliance if water leaks from the pump or flexible 

hoses.

10.  DO NOT

 run the pump dry.

11. 

There are no serviceable components within this appliance.

12.

  When this appliance has reached the end of its serviceable life, it should 

be disposed of in a safe manner, in accordance with current local authority 

recycling, or waste disposal policy.

Содержание Mira 1.5

Страница 1: ...1 Mira 1 5 bar Twin Ended Pump Mira 2 0 bar Twin Ended Pump These instructions must be left with the user Installation and User Guide...

Страница 2: ...cordance with the relevant local wiring regulations 8 A separate permanently connected supply to the appliance must be through a double pole switch which has at least 3 mm contact separation 9 Make su...

Страница 3: ...regulations or practices specified by the local electricity supply company 6 The plumbing installation must comply with all national or local water regulations and all relevant building regulations or...

Страница 4: ...riginal packaging Guarantee For domestic installations Mira Showers guarantee the Mira 1 5 bar Twin Ended Pump and the Mira 2 0 bar Twin Ended Pump against any defect in materials or workmanship for a...

Страница 5: ...familiarise yourself with the part names and to confirm that all parts are included 1 x Mira 1 5 or 2 0 bar Twin Ended Pump only one supplied 4 x Flexible Hoses 4 x Sealing Washers Documentation 1 x...

Страница 6: ...6 DIMENSIONS 231 166 96 132 38 103 5 All dimensions are nominal and in millimetres Fig 1 Electrical Supply Lead 1500 mm 1 5 m...

Страница 7: ...50 Hz Protection Rating IPX2 Type of Motor Induction Power Consumption 385 W 420 W Full Load Current 1 7 A 1 8 A Rating Int S3 30 mins on 30 mins off 9 l min Both ends pumping Maximum Number of Starts...

Страница 8: ...8 Mira 1 5 2 0 bar Twin Ended Pumps Performance Graph 0 5 10 15 2 0 b a r 1 5 b a r 20 0 5 10 15 20 25 30 35 40 FLOW l min HEAD metres 0 0 0 5 1 0 1 5 HEAD bar...

Страница 9: ...age may go undetected or cause damage The pump must be installed such that it is accessible for servicing or removal When servicing or disconnecting small amounts of water may drain from the unit and...

Страница 10: ...e pump to the mounting surface 10 The pump must have a minimum flooded suction head of 0 5 metres at all times 11 The pump must be installed in a positive head position a gravity flow of approximately...

Страница 11: ...stem Layout for Mira Twin Ended Pump Fig 4 DHW Pump Mixing Valve Cistern Max Inlet Head 10 m Max Inlet Head 10 m Min Inlet Head 0 5 m Min Inlet Head 0 5 m Full bore Isolator valves MUST be fitted to i...

Страница 12: ...12 DHW Pump Unsuitable Layout for Mira Twin Ended Pump Fig 5 Cistern Mixing Valve Cistern Unsuitable Layout for Mira Twin Ended Pump Fig 6 DHW Pump Mixing Valve...

Страница 13: ...k configurations which can allow air locks to form should be avoided For inlet pipework this should be achieved by utilising pipe runs with a continuous fall For outlet pipework either provide a conti...

Страница 14: ...to the pump Fitting the Hose to Pipework The hoses are fitted with plastic push in connectors which must only be connected with the following a 15 mm diameter copper pipe to BS EN 1057 R250 half hard...

Страница 15: ...g hold the collet down and gently remove the pipe If the system has been filled with water care should be taken to isolate the pump and towels used to absorb any spilled water 10 Make sure that any pi...

Страница 16: ...16 15 mm PIPE 22 mm PIPE 30 Max 22 mm PIPE Fig 10 Plumbing Connections ANTI VIBRATION FOOT PUMP BODY FLEXIBLE HOSES Do not kink or twist...

Страница 17: ...or any particular regulations or practices specified by the local electricity supply company The installation must be carried out by a competent person 2 In the interests of electrical safety a 30 mA...

Страница 18: ...the continuity has been broken by flexible hoses or plastic components Adjacent suction and delivery pipes should be fitted with earthing clamps to BS 951 and connected with earthing wire size 4 mm s...

Страница 19: ...itre min from the highest outlet WARNING Do Not switch on if there is a possibility that the water in the appliance is frozen 4 With the electrical supply isolated prime the pump by turning on the wat...

Страница 20: ...n and other restrictions 5 Check the system has adequate flow rate for the pump to operate refer to section Installation 6 The flow switch mechanism is sticking Contact Mira Showers see back cover to...

Страница 21: ...rs shower hose head etc 4 The pump is noisy in operation Note All pumps generate some noise Installation conditions may allow this to be amplified a Installation fault 1 Vibration from the pump body t...

Страница 22: ...e should be of spring loaded pattern and fitted in the discharge pipework This may increase the minimum head pressure required to operate the flow switch MAINTENANCE General Mira products are precisio...

Страница 23: ...ior to use Manufactured on behalf of Kohler Mira by Stuart Turner Ltd Henley on Thames Oxfordshire RG9 2AD DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY 2006 42 EC BS EN ISO 12100 1 BS EN ISO 12...

Страница 24: ...s of use of the product or consequential loss of any kind Damage or defects caused if the product is repaired or modified by persons not authorised by us or our appointed representative Routine mainte...

Отзывы: