User maIntenance

If you require a mira trained service engineer or 

agent, refer to section: 

‘Customer Services’

.

Fault Diagnosis

Symptom:

Only hot or cold water from the mixer outlet.

• 

Outlet temperature too hot / too cold.

• 

Cause Rectification:

Inlets reversed (hot supply to cold supply). 

• 

Rework inlet pipework.
No hot water reaching mixer.

• 

Check the filters for any blockage.

• 

Installation  conditions  outside  operating 

• 

parameters, refer to sections: 

‘Specifications’ 

and 

‘Commissioning’

.

—————————————

Symptom:

Fluctuating or reduced flow rate.

• 

Cause Rectification:

Check the shower handset, hose and filters 

• 

for any blockage.

Make sure that the maintained inlet pressures 

• 

are nominally balanced and sufficient, refer 

to section: 

‘Specifications’

.

Make  sure  that  the  inlet  temperature 

• 

differentials  are  sufficient,  refer  to  section: 

‘Specifications’

.

Flow regulator fitted incorrectly.

• 

Air lock or partial blockage in the pipework.

• 

—————————————

Symptom:

Water leaking from shower handset.

• 

Cause Rectification:

Normal for a short period after shut off.

• 

Check that the pressures are not in excess of 

• 

the specifications for the product.
Renew the mixer valve assembly.

• 

Lubricants

silicone based lubricants must only be used on 

the rubber seals. 

Caution!

 oil based or other lubricant types may 

cause rapid deterioration of seals.

Cleaning

the chrome plated parts should be cleaned using 

a  mild  washing  up  detergent  or  soap  solution, 

rinsed and then wiped dry with a soft cloth.

Warning!

  many  household  cleaners  contain 

abrasive and chemical substances, and should not 

be used for cleaning plated or plastic fittings.
These  finishes  should  be  cleaned  with  a  mild 

washing up detergent or soap solution, and then 

wiped dry using a soft cloth.
Use  your  thumb  or  a  soft  cloth  to  wipe  any 

limescale  from  the  soft  nozzles  and  the  front 

surface of the handset spray plate.

Do not 

use descalents on this product.

Содержание Infuse

Страница 1: ...1 Installation User Guide These instructions must be left with the user Thermostatic Mixers Mira Infuse Mira Minibelle...

Страница 2: ...afe level Inlet filters are fitted to protect the thermostatic cartridge Patents Patents GB 2 340 210 2 392 223 2 392 224 Patent Applications Euro 1 672 257 US 2006 0124758 A1 Contents Introduction 2...

Страница 3: ...the infirm or anyone inexperienced in the correct operation of the controls 6 Rapid Excessive movement of the flow and or temperature control levers may result in momentary unstable blend temperatures...

Страница 4: ...damage however this could detrimentally affect thermostatic performance For safety and performance reasons it is recommended that the maximum hot water temperature is limited to 65 C Cold Water Range...

Страница 5: ...egulations and practices specified by the local water company or water undertakers Note Make sure that all site requirements correspond to the information given in section Specifications 1 The Mixer m...

Страница 6: ...inlets 2 Determine the route for the hot and cold supply pipework Hot Cold Outlet 4 Loosen the 2 backplate grubscrews with the 2 mm hexagon key supplied and pull the mixer and concealing plate from th...

Страница 7: ...mixer Failure to do so may result in product malfunction and will not be covered under the guarantee 11 Fit the olives onto the inlet pipework and tighten the inlet nuts using a suitable spanner Caut...

Страница 8: ...tant A 12 litre minute flow regulator is fitted inside the outlet nipple This can be removed for gravity fed other low pressure systems 0 5 bar or below Hose Washer 12 L Min Flow Regulator 15 Turn on...

Страница 9: ...it back one serration on the temperature control gear 6 Return the lever to the maximum temperature stop and check the temperature if it is still not hot enough repeat the procedure Lift the temperat...

Страница 10: ...gulator fitted incorrectly Air lock or partial blockage in the pipework Symptom Water leaking from shower handset Cause Rectification Normal for a short period after shut off Check that the pressures...

Страница 11: ...k Minibelle 1660 156 Temperature Knob Pack Infuse 1660 150 Backplate 1660 151 Concealing Plate 1660 154 Mixer Valve Assembly 1660 153 Inlet Nuts Olives x2 1660 152 Filter Pack x2 Not illustrated 1660...

Страница 12: ...Services Team is comprehensively trained to provide every assistance you may need help and advice spare parts or a service visit Spare Parts We maintain an extensive stock of spares and aim to provid...

Отзывы: