sPeCIFICaTIons
Pressures
Max Static Pressure:
•
10 Bar
.
Max Maintained Pressure:
•
5 Bar
.
Min Maintained Pressure: (Gas Water Heater):
•
1.0 Bar
. (for optimum
performance supplies should be nominally equal.)
Min Maintained Pressure (Gravity System):
•
0.1 Bar
. (0.1 bar = 1 Metre head
from cold tank base to shower handset outlet.)
Temperatures
Close temperature control is provided between
•
20°C and 50°C
.
Optimum Thermostatic Control Range:
•
35°C to 45°C
. (achieved with supplies
of 15°C cold, 65°C hot and nominally equal pressures.)
Recommended Hot Supply:
•
60°C to 65°C
. (
note!
The mixing valve can operate
at temperatures up to 85°C for short periods without damage. However for
safety reasons it is recommended that the maximum hot water temperature is
limited to 65°C.)
Minimum Differential between Hot Supply and Outlet Temperature:
•
10°C
.
Cold Water Range:
•
5°C - 25°C
.
Thermostatic shut-down
For safety the thermostat will shut off the hot supply
•
within 2 seconds
if the
cold supply fails. (achieved only if the hot supply temperature is greater than
10°C above the set blend temperature.)
Connections
Hot: Left
•
(side nearest flow control), ½” BSP Male.
Cold: right
•
(side nearest temperature control), ½” BSP Male.
outlet: Bottom
•
, ½” BSP Male to flexible hose.
note!
This product does not allow for reversed inlets and will deliver unstable
temperatures if fitted incorrectly.
Offset connector (inlet centres are 150 mm ± 24 mm).
½" BSP
Connection to Pipework
¾" BSP
Connection to Bar Valve