Mira 1559.006 Скачать руководство пользователя страница 17

P4297

User Operation

P4297080

ON

OFF

HOT

COLD

Pull 'DOWN' to divert
water to shower

17

For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www.mytub.co.uk

Содержание 1559.006

Страница 1: ...1559 007 Important Please quote the above model number s when ordering spares IMPORTANT Installer This manual is the property of the customer and must be retained with the product for maintenance and...

Страница 2: ...Finish the Installation 16 User Operation 17 User Operation Shower Fittings 18 USER MAINTENANCE 19 Cleaning 19 Spray Plate Assembly External 19 Spray Plate Removal 20 Spray Plate Assembly Internal 21...

Страница 3: ...P4297 After Sales Service 28 Spare Parts 28 3 For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www mytub c...

Страница 4: ...sioned operated and maintained in accordance with the recommendations given in this Manual 2 Periodic attention is given as necessary to maintain the product in good functional order Recommended guide...

Страница 5: ...P4297 DIMENSIONS P4297010 1 2 BSP 1 2 BSP Wall Mounted BSM 5 For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www mytub c...

Страница 6: ...P4297 P4297020 180 mm 1 2 BSP 164 mm 3 4 BSP 69 mm 3 4 BSP Deck Mounted BSM 6 For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www mytub c...

Страница 7: ...rating pressure is 1 0 bar to enable correction of the bath shower divertor Plumbing Connections Hot H and Cold C inlets must be connected to the correct inlet supplies 7 For latest prices and deliver...

Страница 8: ...who is registered with or is a member of an association such as Institute of Plumbing IOP throughout the UK National Association of Plumbing Heating and Mechanical Services Contractors NAPH MSC Englan...

Страница 9: ...r Connectors Mixer Assembly Seal 1 Position the seals into the mounting nuts on the back of the mixer 2 Screw the two pillar connectors into the mixer hand tight 9 For latest prices and delivery to yo...

Страница 10: ...ply a ring of sealant in accordance with the manufacturer s instructions underneath the sealing plates 5 Fit the mixer through the top of the bath 6 Install the washers and the locknuts Use a tap span...

Страница 11: ...nstall the connectors in the wall and connect to the hot and cold supply hot supply to left cold supply to right P3911150 150mm Spirit Level 2 Make sure that the connectors are level and set at the co...

Страница 12: ...amage Make sure you protect the chrome plated surfaces when you tighten the nuts 4 Align the mixer and connectors and tighten the nuts using a suitable spanner 12 For latest prices and delivery to you...

Страница 13: ...the wall and mark the positions of the fixing holes 3 Drill the 8 mm holes for the fixing screws and insert the wall plugs supplied Note Alternatively use proprietary cavity fixings for dry lined stud...

Страница 14: ...5 Clip the bottom part of the parking socket over the top part of the parking socket 6 Attach the hose to the adjustable handset and the bath shower mixer 14 For latest prices and delivery to your do...

Страница 15: ...P4297 P4302260 Parking Socket Adjustable Handset 7 Park the handset assembly in the parking socket 15 For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www mytub c...

Страница 16: ...er supply and check for leaks from both the mixer 6 Remove the aerator from the spout 7 Turn on the mixer lever and push lever as far to the left hot water and to the right cold water as possible to r...

Страница 17: ...P4297 User Operation P4297080 ON OFF HOT COLD Pull DOWN to divert water to shower 17 For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www mytub c...

Страница 18: ...anticlockwise until it Clicks one click from the eco setting Water will flow from the outer set of holes pllqeb To access the soothe setting turn the spray plate anticlockwise until it Clicks two clic...

Страница 19: ...ned using a mild washing up detergent or soap solution rinsed and then wiped dry with a soft clean cloth Regularly dismantle and clean the aerators to keep water flow regular Spray Plate Assembly Exte...

Страница 20: ...P4302220 1 Turn the adjuster ring fully clockwise 2 Unclip and remove the adjuster ring 3 Unscrew the spray plate assembly in an anticlockwise direction The O seals will provide some assistance 4 Rem...

Страница 21: ...o Spray Plate Removal and Installation 2 Remove the inner and outer nozzle ring retainers 3 Clean the components with a stiff brush If necessary use a plastic kettle descalent in accordance with the m...

Страница 22: ...stallation Nozzle Ring Replacement Inner Nozzle Ring Retainer Outer Nozzle Ring Retainer Spray Plate Assembly P4302230 1 Remove the spray plate 2 Remove both the inner and outer low capacity nozzle ri...

Страница 23: ...er nozzle ring retainer onto the spray plate assembly 3 Fit the outer nozzle ring retainer onto the flow divertor 4 Turn the flow divertor fully clockwise 5 Carefully screw the spray plate assembly on...

Страница 24: ...P4297 SPARE PARTS P4297095 1559 006 1559 007 24 For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www mytub c...

Страница 25: ...ge R29928438 Divertor 460 16 Handle Assembly E84174 CP Deck Mounted Connection E75414 CP Wall Mounted Connection 450 35 Adjustable Handset 460 18 Handset Holder 150 60 Shower Hose 25 For latest prices...

Страница 26: ...P4297 NOTES 26 For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www mytub c...

Страница 27: ...P4297 NOTES 27 For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www mytub c...

Страница 28: ...er GL52 5EP For Customers in Northern Ireland Wm H Leech Son Ltd Telephone 028 9044 9257 Mon to Fri 9am 5pm Fax 028 9044 9234 24 hours By Post Maryland Industrial Estate Ballygowan Road Moneyreagh Co...

Отзывы: