7
GB/IE/NI
m
CAUTION!
Change the temperature limiter
setting only after the tap has been installed.
Follow Fig. I to set the temperature limitation.
Turn off the main water supply.
Remove the chrome cap
3
carefully by a
small flat screwdriver.
Release the locking screw
2
by turning it
anticlockwise using the hexagonal key
7
.
m
CAUTION!
Do not take the screw
2
completely out; just loosen it until the control
lever
1
can be easily taken off.
Take off the control lever
1
.
Loosen the cartridge covering ring
20
by
hand, then screw off the cartridge retaining
ring
21
by using a pipe wrench.
Now pull the adjusting ring
22
upwards with
the help of a screwdriver.
Note:
Do not remove the cartridge
23
.
Place the adjusting ring
22
in the desired
position (see Fig. I).
Tighten the cartridge retaining ring
21
onto
the tap body
5
again by using a pipe
wrench. Then tighten the cartridge covering
ring
20
by hand.
Place the control lever
1
back on to the
tap body
5
. Tighten the locking screw
2
by turning it clockwise using the hexagonal
key
7
.
Press the chrome cap
3
into the opening.
Turn on the main water supply and check the
temperature limiter.
Water-saving function
The cartridge
23
in this tap has an Eco-Click
function. This feature limits the water flow
through the tap. This means you can save up
to 50 % water (see Fig. J).
Lift the lever until you notice a slight
resistance. This resistance will cause a stop
in case of partial opening and will therefore
simply limit the flow of water.
If you want to increase the flow rate,
exert slight pressure on the lever until you
overcome the resistance.
Energy-saving function
The cartridge
23
in this tap has an energy
function.
Only cold water will flow out when the
control lever
1
is set to the middle position,
and thus reduce energy consumption (see
Fig. K).
Maintenance and cleaning
Tap care and cleaning
Please note that sanitary fittings require special
care and attention. Therefore you should follow
the following advice:
Never use corrosive or alcohol-based
materials for cleaning, as these could
damage the product.
Clean your fittings with clean water, mild
detergent and a soft cloth or leather only.
Screw out the aerator
24
at regular intervals
and remove lime deposits or foreign bodies.
Non-observance of the above care advice can
be expected to result in damage to the surface
of the fittings. In this event your rights under the
warranty may be invalidated.
Содержание HG03546A
Страница 4: ...E 10 11 8 9 15 27 max 32 mm 10 11 15 8 9 max 50 mm ...
Страница 5: ...F ...
Страница 6: ...G H I 24 20 23 21 22 7 3 2 1 J K 8 0 º 30º 1 0 2 1 0 2 23 22 ...