BATTERY SYSTEM
Typical Recharge Time
Typical Battery Life
Battery Module Part #
BM0043
From Full load dishcarge: 4-hours to 80%, 8-hours to 90%
BM0044
Battery Type
Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid
Runtime: Full Load (minutes)
Runtime: Half Load (minutes)
SURGE PROTECTION AND FILTERING
Audible Noise at 1 m (3 ft.)
10/100 Base-T surge protection let-through
(as a percentage of an a/-6 kV 1.2/50
us, 500 a 8/20 uS test)
Telephone line surge protection let-through
(as a percentage of an a/-6 kV 1.2/50
us, 500a 8/20 uS test)
Noise Filter
Surge voltage let-through (as a percentage
of an applied ANSI C62.41 Cat. A +/-6 kV)
Surge Response Time
Surge Current Capability
Surge Energy Rating
1140 J
0 ns (instantaneous) normal mode; <5 ns common mode
< 5%
>45db normal and common mode EMI/RFI suppression
<45 dBA
< 1%
< 5%
6500 Amps total
PHYSICAL
Weight - Net
Size - Net
L X W X H
Size - Shipping
L X W X H
Weight - Shipping
15.7 x 17.3 x 3.5"
398 x 440 x 89 mm
20.7 x 21.9 x 8.5"
526 x 555 x 215 mm
43.0 lbs
19.5 Kgs
48.5 lbs
22.0 Kgs
ENVIRONMENTAL
Operating/Storage Humidity
95% Non-Condensing
Storage Elevation
0 to 15,000m (0 to +50,000 ft)
Storage Temperature
-15 to +45
°
C (+5 to +113
°
F)
Operating Temperature
0 to 40 degrees C (+32 to +104 degrees F) at
Operating Elevation
0 to 1,500m (0 to +5,000 ft)
Operating Temperature
0 to 35 degrees C (+32 to +95 degrees F) at
Operating Elevation
1501 to 3,000m (0 to +10,000 ft)
35.1 lbs
15.9 Kgs
40.8 lbs
18.5 Kgs
17
5
17
5
English
120VAC
1000VA
700W
Protection
Waveform Type
Over-Current, Short-Circuit Protected and Latching Shutdown
Simulated Sine Wave (Step Wave)
Frequency
50/60Hz, +/-0.5Hz (unless synchronized to utility)
Nominal Voltage
Maximum Power Capacity
6 ms Typical
>90% (Full Load)
Resettable Circuit Breaker
50 or 60 Hz, +/-5Hz, autosensing
0 - 160VAC
90 - 150VAC
104 - 132VAC
Transfer Time
Efficiency (Line Mode)
Input Protection
Frequency Limits
Voltage Range
Acceptable Input voltage
PRO1000RT
Model Number
SYSTEM SPECIFICATIONS
Voltage Range
Topology
Line-Interactive, Simulated Sine Wave
OUTPUT NON-BATTERY OPERATION
INPUT
Number of Phase
Single (1
∅
2W +G)
Nominal Voltage
120VAC
Low Voltage Transfer Point
90V resets to Utility Power at 94V or higher
High Voltage Transfer Point
150V resets to Utility Power at 146V or lower
Voltage Regulation
120VAC: -13.3% - +10.0%
Frequency Range
60Hz: 55 - 65Hz or 50Hz: 45 - 55Hz
OUTPUT BATTERY OPERATION
Voltage Regulation
N/-5% (until Low Battery Warning)
Overload Capacity
PRO1500RT
1500VA
1050W
REGULATORY COMPLIANCE
Safety and Approvals
EMC Verification
cTUVus
(conforms to UL1778, CSA 22.2 standards)
FCC Class B, CE certified
3 to 5 years.
Environmental factors do affect battery life.
High temperatures, poor utility power, and frequent, short
duration discharges have a negative impact on battery life.
AC Mode: 110% for 5-seconds then fault, 120% Shutdown Immediately
DC Mode: 110% for 10-seconds then shutdown, 120% Shutdown Immediately