REAR PANEL

English

5

4

3

2

1

9

8

6

7

1. The Information/Rating Label.

2. The Battery Backup and Surge output power receptacles are NEMA 5-15R
    type.

3. The USB Communications Interface Port is for UPS monitoring and control.

4. The Surge ONLY output power receptacles are NEMA 5-15R type.

5. The Dipswitches are for setting the Inverter output voltage and the transfer
    set points.

6. The input power cord has a NEMA 5-15P Plug.

7. The input circuit breaker will trip in the event the load exceeds the UPS’s
     power rating.

8. The RJ11/RJ45 modular connectors are used for 10 Base-T Network/Fax/
     Modem protection.

9. The Site Wiring Fault (SWF) LED illuminates when the UPS detects an
      improperly wired AC wall outlet.

Содержание MBK-E SERIES

Страница 1: ......

Страница 2: ...duction 2 2 Controls and Indicators 5 3 Installation 7 4 Operation 9 5 Troubleshooting 11 6 Replacing the Battery 12 7 Obtaining Service 15 8 Specifications 16 9 Configurable Parameters Settings 17 10...

Страница 3: ...d factory service if it is required If you experience a problem with the UPS please refer to the Troubleshooting guide in this manual to correct the problem or collect enough information so that the M...

Страница 4: ...ipment may cause interference to radio and television reception If this equipment does cause interference to radio or television reception which can be determined by turning the equipment off and on t...

Страница 5: ...systems peritoneal dialysis systems neonatal ventilator incubators ventilators for both adults and infants anesthesia ventilators and infusion pumps as well as any other devices desig nated as critica...

Страница 6: ...C power to the load The LED blinks and the audible alarm sounds when supplying battery power to the load The LED blinks and no audible alarm when the UPS is in the boost mode The Fault red LED illumin...

Страница 7: ...er receptacles are NEMA 5 15R type 5 The Dipswitches are for setting the Inverter output voltage and the transfer set points 6 The input power cord has a NEMA 5 15P Plug 7 The input circuit breaker wi...

Страница 8: ...50 000 ft INSTALLATION Be sure to read the installation placement and all the cautions before installing the UPS Place the UPS in the final desired location and complete the rest of the installation p...

Страница 9: ...N OPTIONAL MINUTEMAN Power Monitoring Software and interface cables kits can be used with the MBK E Series UPS Use only MINUTEMAN or MINUTEMAN ap proved interface cables with these UPSs Connect the US...

Страница 10: ...is longer than the start up or user invoked test This test will run for approximately fifteen seconds to measure the battery s capability to provide an acceptable amount of runtime If the UPS fails a...

Страница 11: ...tteries pass a self test If the battery is bad or disconnected the Weak Bad Battery LED will illuminate and the alarm will beep three times every five min utes until the battery is reconnected or repl...

Страница 12: ...cations port Site Wiring Fault LED is illuminated Have a Qualified Electrician correct the service wiring The batteries may be weak or at the end of useful service life Charge the batteries for 8 hour...

Страница 13: ...ies properly The batteries contain lead and pose a hazard to the environment and human health if not disposed of properly Refer to local codes for proper disposal requirements or return the battery to...

Страница 14: ...n the front panel to turn the UPS OFF 3 Unplug the UPS s AC power cord from the AC wall outlet 4 Unplug the equipment from the output receptacles of the UPS 5 Unplug the computer interface cable from...

Страница 15: ...6 Re install the battery bracket and the battery bracket retaining screw 17 Verify proper polarity Reconnect the battery negative black wire to the battery negative terminal 18 Verify proper polarity...

Страница 16: ...s if possible F A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue...

Страница 17: ...current capability one time 8 20 uS waveform 6500 Amps total Surge energy rating one time 10 1000 uS waveform Protection On battery waveshape Over current short circuit protected and latching shutdow...

Страница 18: ...ry disabled 120 127VAC At first battery replacement reset to reflect actual number of days experience in your environment or leave factory default Enter the current date when replacing batteries Use t...

Страница 19: ...arranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase The warranty shall be void if a the equipment is damaged by the customer is impr...

Страница 20: ...s or otherwise The sole and exclusive remedy for breach of any warranty expressed or implied concerning Para Systems s prod ucts and the only obligation of Para Systems hereunder shall be the repair o...

Страница 21: ...urer s Address 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Model No MBK550E MBK750E I the undersigned hereby declare that the equipment specified a...

Страница 22: ...21 Notes English...

Страница 23: ...22 English Notes...

Страница 24: ...23 Page do not print...

Отзывы: