background image

5

4

Life Support Policy

As a general policy, we do not recommend the use of any of our products in life
support applications where failure or malfunction of the product can be reason-
ably expected to cause failure of the life support device or to significantly affect
its safety or effectiveness.  We do not recommend the use of any of our prod-
ucts in direct patient care.  We will not knowingly sell our products for use in
such applications unless it receives in writing assurances satisfactory to us
that (a) the risks of injury or damage have been minimized,  (b) the customer
assumes all such risks, and (c) our liability is adequately protected under the
circumstances.

After removing your UPS from its carton, it should be inspected for damage that
may have occurred in shipping.  Immediately notify the carrier and place of
purchase if any damage is found.  Warranty claims for damage caused by the
carrier will not be honored.  The packing materials that your UPS was shipped
in are carefully designed to minimize any shipping damage.  In the unlikely
case that the UPS needs to be returned to the manufacturer, please use the
original packing material.  Since the manufacturer is not responsible for ship-
ping damage incurred when the system is returned, the original packing mate-
rial is inexpensive insurance.  

PLEASE SAVE THE PACKING MATERIALS!

Receiving Inspection

NOTE:

  These UPSs are shipped with the batteries disconnected.  The batter-

ies must be connected before putting these UPSs into service.  Refer to Sec-
tion 3 "Installation" for connecting the batteries.

NOTICE:   

This equipment has been tested and found to comply with the limits

for a Class B computing device in accordance with the specifications in Sub-
part J of Part 15 of FCC Rules and the Class B limits for radio noise emissions
from digital apparatus set out in the Radio Interference of the Canadian Depart-
ment of Communications.  These limits are designed to provide reasonable
protection against such interference in a residential installation.  This equip-
ment generates and uses radio frequency and if not installed and used properly,
that is, in strict accordance with the manufacturer's instructions, this equip-
ment may cause interference to radio and television reception.  If this equip-
ment does cause interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:

Reorient the receiving antenna.

Relocate the computer with respect to the receiver.

Move the computer away from the receiver.

Plug the computer into a different outlet so that the computer and receiver
are on different branch circuits.

Shielded communications interface cables must be used with this product.

WARNING:  

Changes or modifications to this unit not expressly approved by

the party responsible for compliance could void the user's authority to operate
the equipment.

ON / OFF / TEST BUTTON:  

To turn the UPS on: press and hold the

On/Off/Test Button until the alarm sounds one beep and then release.
The UPS will perform a five second battery test.  Once the UPS has
passed the battery test the UPS will reset to the norml AC mode and
provide power to the connected load.  To turn the UPS off:  press and
hold the On/Off/Test Button until the alarm sounds one beep and then
release.  To perform a ten-second battery test:  With the UPS in the
normal AC mode, press and hold the On/Off/Test Button until the
alarm sounds four beeps, and then release.  During the test, the
UPS will switch to the Battery mode, the On-Battery icon will illumi-
nate and the alarm will sound.

NOTICE!

  The output of this device is not sinusoidal.  It has a total harmonic

distortion and maximum single harmonic as below:
EP500LCD

Total harmonic: 43.1%

Single harmonic: 30.7%

EP700LCD

Total harmonic: 46.5%

Single harmonic: 35.9%

EP1000LCD

Total harmonic: 36.3%

Single harmonic: 19.0%

EP1500LCD

Total harmonic: 33.6%

Single harmonic: 13.3%

© COPYRIGHT 2015 BY PARA SYSTEMS, INC.

All Rights Reserved. All rights of this User Manual (“Manual”), including but not
limited to the content, information, and figures are solely owned and reserved
by Para Systems, Inc. (“Para Systems”). The Manual can only be applied to
the operation or the use of this product. Any disposition, duplication, dissemi-
nation, reproduction, modification, translation, extraction, or usage of this
Manual in whole or in part is prohibited without the prior written permission of
Para Systems. Given that Para Systems will continuously improve and de-
velop the product, changes may be made to the information in this Manual at
any time without obligation to notify any person of such revision or changes.
Para Systems will make all possible efforts to secure the accuracy and the
integrity of this Manual. Para Systems disclaims any kinds or forms of war-
ranty, guarantee, or undertaking, either expressly or implicitly, including but
not limited to the completeness, faultlessness, accuracy, non-infringement,
merchantability or fitness for a particular purpose of the Manual.

Содержание Entrepid Series

Страница 1: ...User s Manual Entrepid Series UPS Para Systems Inc 1455 LeMay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000491 R3...

Страница 2: ...rols and Indicators 6 3 Installation 8 4 Operation 11 5 Troubleshooting 14 6 Replacing the Battery 15 7 Obtaining Service 18 8 Specifications 19 9 Limited Product Warranty 21 A1 Declaration of Conform...

Страница 3: ...the battery CAUTION To reduce the risk of electrical shock in conditions where the load equipment grounding cannot be verified disconnect the UPS from the AC wall outlet before installing a computer i...

Страница 4: ...interference by one or more of the following measures Reorient the receiving antenna Relocate the computer with respect to the receiver Move the computer away from the receiver Plug the computer into...

Страница 5: ...d Capacity Bar Graph Displays the amount of load connected to the UPS in the AC and Battery mode 3 AC normal and Boost Buck mode Icon Illuminates when the UPS is in the AC normal mode and flashs when...

Страница 6: ...ttery life is 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges have a negative impact on battery life This UPS seri...

Страница 7: ...se The UPS may be used immediately however the On Battery runtime may be less than normally expected Typical battery life is 3 to 5 years Environmental factors do affect battery life High temperatures...

Страница 8: ...t operation of the UPS and the condition of the batteries The start up and user invoked test will run for approximately ten seconds to measure the battery s capability to support the output load If th...

Страница 9: ...tion discharges have a negative impact on battery life Possible Cause Symptom What To Do Press hold and then release the On Off button to start UPS On Off Test button not pressed UPS will not turn on...

Страница 10: ...computer interface cable from the rear panel of the UPS 6 Remove the front panel retaining screws on the bottom side of the front pa nel FIG 1 FIG 1 12 Grasp the battery pull tab and gently pull the b...

Страница 11: ...der to avoid damage in transit Never use Styrofoam beads for a packing material a Include a letter with your name address day time phone number RMA number a copy of your original sales receipt and a b...

Страница 12: ...ystems Para Systems pays ground freight to ship the product back to the customer Replacement parts and warranty labor will be borne by Para Systems For equipment located outside of the United States a...

Страница 13: ...000 4 11 UL1778 FCC Class B Manufacturer s Name Para Systems Inc MINUTEMAN UPS Manufacturer sAddress 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Uninterruptible Power Supplies UPS Mo...

Отзывы: