Minuteman Ambassador C46000-00 Скачать руководство пользователя страница 2

1

FOR COMMERCIAL USE ONLY

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precautions should always be followed, including the
following:

READ ALL INSTRUCTIONS BEFORE USING
WARNING

 - 

To reduce the risk of fire, electric shock, or injury:

• Do not leave appliance when plugged in.  Unplug from outlet when not in use and

before servicing.

WARNING

To reduce the risk of electrical shock, do not expose to rain. Store indoors.

Never allow children or untrained adults to operate this equipment.

Keep the area of operation clear of all persons, particularly small children,
and pets.  Keep bystanders at least 25 feet away from the area of operation.

Use only as described in this manual.  Use only manufacturer’s recommended
attachments.

Do not use with damaged cord or plug.  If appliance is not working as it
should, has been dropped, damaged, left outdoors, or dropped into water,
return it to a service center.

Do not pull or carry by cord, use cord as a handle, close a door on cord, or
pull cord around sharp edges or corners.  Do not run appliance over cord.
Keep cord away from heated surfaces.

Do not unplug by pulling on cord.  To unplug, grasp the plug, not the cord.

Do not handle plug or appliance with wet hands.

Do not put any object into openings.  Do not use with any opening blocked;
keep free of dust, lint, hair, and anything that may reduce air flow.

Keep hair, loose clothing, fingers, and all parts of body away from openings
and moving parts.

Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.

Do not use without dust-bag and/or filters in place.

Turn off all controls before unplugging.

Use extra care when cleaning on stairs.

Do not use to pick up flammable or combustible liquids such as gasoline or
use in areas where they may be present.

Connect to a properly grounded outlet only.  See grounding instructions.

If foam/liquid comes out of exhaust openings turn switch off immediately.

Use only chemicals recommended by dealer/manufacturer.

SAVE THESE INSTRUCTIONS

Содержание Ambassador C46000-00

Страница 1: ...Model C46000 00 C46100 00 Ambassador Revised 9 03 OPERATION SERVICE PARTS CARE ...

Страница 2: ...ce center Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Do not run appliance over cord Keep cord away from heated surfaces Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not handle plug or appliance with wet hands Do not put any object into openings Do not use with any opening blocked keep free of dust l...

Страница 3: ...stance for electric current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Improper connection of the equipment grounding conductor can result in a risk of electri...

Страница 4: ...connections Check electrical cable for abrasion or cuts in jacket Cord should be replaced if worn or damaged 7 Clean float assembly and check for signs of damage MONTHLY BI MONTHLY MAINTENANCE The Ambassador Solution Pump System should be purged twice monthly to remove alkaline residue build up The system should be flushed twice once with the jets installed and once with jets removed To flush syst...

Страница 5: ... gauge reads in green zone 6 Solution pump should be turned off to the center switch position page 5 6 before the end of each cleaning pass During the cleaning cycle care should be taken not to allow foam to build up in the recovery tank If this should happen the machine should be turned off Defoamer order 910543 should be added to the recovery tank only never into the solution tank Foam should no...

Страница 6: ...n is for intermittent spray for cleaning in smaller more confined areas When released switch will return to center off position 7 Pump auxiliary when using separated floor tool or upholstery tool switch must be switched to on position See figure 2 for solution hose hook up aux out 8 Brush pressure adjustment gauge See figure 2 for brush adjustment knob location Adjustments past the green zone on g...

Страница 7: ...Y SYSTEM 1 Waste Water Recovery Hose Grey hose cuff to grey fitting 2 Recovery Waste Water Diffuser 3 Vac Hose White Cuff White hose cuff to white fitting 4 Vac Shut Off Float INSTRUCTIONS FOR CONNECTING E T MOTORIZED HAND TOOL TO AMBASSABOR EXTRACTOR ...

Страница 8: ...7 ...

Страница 9: ...8 ...

Страница 10: ... 4 80 712760 6 WSR Flat 56 x 1 06 x 04 SS ITEM PART NO QTY DESCRIPTION 81 711523 1 WSR Wave 37 x 68 x 08 82 711594 11 WSR Flat 56 x 88 x 03 NI 83 711713 4 Retaining Ring E Ext 50 84 711717 2 Retaining Ring E Ext 37 85 711808 2 Cotter Pin Hair No 13 86 712101 17 SCR MC HH WSR 10 24 x 50 87 712533 1 SCR MC 10 24 x 1 25 SS 88 712540 6 SCR MC 10 24 x 37 SS TH 89 712560 5 SCR MCH 1 4 20 x 50 SS NYL 90 ...

Страница 11: ...10 ...

Страница 12: ...e of replacement filters and or prefilters not manufactured by Minuteman International Inc or its designated licensees will void all warranties expressed or implied A potential health hazard exists without exact original equipment replacement All warranteed items become the sole property of Minuteman International Inc or its original manufacturer whichever the case may be Minuteman International I...

Отзывы: