28.2 Changing Configuration
The MSR configurations can be changed through software installed on the system. They
are factory preset and normally do not need to be changed by the user.
To enter the setting mode:
Connect keyboard to your MP5000i2 computer.
Run .MSR213U setting AP
Follow instructions on the screen to change settings
28.3 Optional 2x20 LCD Character Display
The 2x20 character display is an alpha numeric LCD with back light. It is driven by a serial
interface controller and normally set at COM4. The board receives control and character
codes which are then displayed on the LCD. This is a receive-only device.
28.4 Power-Up Initialization
Upon power-up, the controller goes into its initialization sequence. The board is
designed to initialize in two states:
1.
physical power up
2.
software power up.
After 250mS, the board is ready to receive software power up.
YOU
MUST
SEND THE
BOARD A CLEAR SCREEN COMMAND (HEX 0C) TWO TIMES AT HALF SECOND INTERVALS.
This will initialize the controller completely. The LCD display is
NOT
hot pluggable or hot
swappable!