![Minotair PENTACARE-V12 Series Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/minotair/pentacare-v12-series/pentacare-v12-series_user-manual-and-installation-manual_1803655054.webp)
54
© MINOTAIR Ventilation Inc. - www.minotair.com
(PENTACARE-V12-OWNER'S MANUAL-2019-Rev-014)
3.
A
DJUSTING
I
NDOOR
H
UMIDITY
S
ETTINGS
Press the
P
button for 3 seconds to display the main menu and use the
U
and
D
arrows to
navigate to the “Hum
idity
” submenu.
Press
R
Figure 49
–
Main menu
–
Humidity settings.
“H
UMIDITY
”
SETTINGS SCREEN
There are 4 available options displayed over several screens. Press
D
or
U
to move the
cursor between options. Once the desired option is selected, press
R
to change the
setting (Figure 50).
Figure 50
–
Examples of options to adjust humidity settings and automatic winter adjustment.
3.1 Setpoint:
o
30% to 60%.
Set the desired relative humidity. During the winter months,
a 35% indoor humidity level is ideal (30-50%), while a 45% indoor humidity
level is very comfortable (40-60%). At all time, the indoor humidity setpoint
may be hard to maintain if your house is not airtight.
3.2 Decrease humidity if outside air is below freezing point?
o
YES
. When outside temperature falls below freezing, the humidity setpoint
will progressively decrease to reach 35 % at -15°C (5°F), and as low as 30% at
- 20°C (-4°F) or less. Humidity level cannot be set below 30% for reasons of
comfort and health.
o
NO
. The humidity setpoint will remain unchanged if outside air falls below
freezing point.
3.1